Isotta RX100 Mark VII Instructions Manual Download Page 13

13

NOTEWORTHY

OPENING AND LOCKING THE HOUSING

1. 

The housing can be opened and closed by operating with only one 

hand. When opening, pull the opening knob, then turn the knob 
counter-clockwise until the outside housing opens. 

2. 

Remove the back of the housing by pulling it oblique slightly to 

release the two pins. In this way, it will be possible to separate 
completely the back housing from the front housing. 

3.

 To close, insert the two pins in their slots, insert the pins in the 

space on the opening knob. While applying a gentle pressure on 
the back of the housing screw the knob until the end, and push 
it downwards to secure it safely. If you have not closed the back 
properly you may feel resistance when turning the knob. 

  Open it again and check that camera is properly inserted, pins are in 

their slots, verify the shoulder strap clips have been removed and try again.

4.

 When closing, make sure there is nothing caught between the 

closing surfaces of the two halves of the housing and check that 
O-rings are clean.

   N.B. 

If you do not close the back housing correctly or there is 

something preventing the correct closure of the housing, the camera 
controls cannot work properly.

• 

As for the push buttons and her functions please refer to the in-
struction manual of the camera in use.

• 

To  use  the  built-in  strobe,  mount  the  supplied  diffuser,  fitting  it 
into the groove of the port by placing the largest part in correspon-
dence with the built-in strobe.

• 

To use an external strobe that works in synchrony with the integra-
ted one in the camera is necessary to bring the fiber optic contact in 
front of the built-in strobe using the appropriate optional accessory.

>

>

>

Summary of Contents for RX100 Mark VII

Page 1: ...HOUSINGS and ACCESSORIES for UNDERWATER PHOTOGRAPHY www isotecnic it Instructions for Sony RX100 Mark VI and RX100 Mark VII...

Page 2: ...outstanding performance of our product manufactured using the most advanced technology available You can also view all the products in the line including accessories for the product purchased on the w...

Page 3: ...g 08 Specifications pag 08 Precautions pag 09 Quick start guide pag 10 Parts of the housing pag 11 Mounting the port pag 12 Opening and locking the housing pag 13 Noteworthy pag 13 Troubleshooting pag...

Page 4: ...on Zoom Lever Port LED humidy sensor Accessory Slide Small Window for built in flash Locking knob Front dial REC Flash Lever Mode Dial Control Dial Shutter Lever 1 2 3 7 8 9 11 10 12 4 5 6 IDENTIFYIN...

Page 5: ...Shot RX100 Mark VI and VII REC Instructions Cyber Shot RX100 Mark VI and VII MODE DIAL Instructions Cyber Shot RX100 Mark VI and VII CONTROL DIAL Instructions Cyber Shot RX100 Mark VI and VII All the...

Page 6: ...ceipt no later than thirty 30 days from the date of purchase to Failure to send the completed dated and signed Warranty Certificate within the 30 days timeframe will disqualify you from claiming under...

Page 7: ...n of the Court of Verona Italy 4 Any defect or damage that occurs due to fire and natural disasters environmental pollution and irregular voltage sources 5 Any defect that occurs due to careless or im...

Page 8: ...7 thread for TG5 is also available as standard a M52 thread AllhousingsaremadeentirelyofIsotta ssignaturered coloredanodized aluminum which is anti corodal with depth rate to 330ft 100m With double O...

Page 9: ...When fitting the O rings into the O rings groove insert it straight into the groove do not bend or twist it 4 Store the housing in a robust shock proof container during transportation avoid transporti...

Page 10: ...Apply a slight upward pull to the locking knob and rotate anti clockwise until the pin is visible Slightly lift the Back until it comes out from the guide pin on the knob Remove the Back slantwise pa...

Page 11: ...t will remain steady thanks to the 4 internal plastic supports that block the camera when the housing is closed The back door features all key main camera controls by means of clearly labelled laser e...

Page 12: ...the alignment of the markers placed on both sides and remove it Each time you do this it is necessary to pay particular attention to the o ring present on the extracted part that must be kept clean u...

Page 13: ...Open it again and check that camera is properly inserted pins are in theirslots verifytheshoulderstrapclipshavebeenremovedandtryagain 4 When closing make sure there is nothing caught between the clos...

Page 14: ...LED IS ON A red LED signal indicates excessive moisture inside the housing If this happens underwater you should get out of water as soon as possible in respect of security measures and ensure that th...

Page 15: ...case in direct sunlight as the color might fade and in order to prevent damage to the internal circuitry CHECK that the port is always clean never degrease it with solvents acetone paint thinner etc t...

Page 16: ...tablecloths etc or places of stagnant dust because the grease protects the O rings but attracts various lightweight materials such as fur hair fibres grains of salt sand etc These particles are diffic...

Page 17: ...echnicalupdateswithoutpriornotice It is recommended that you ship the housing to our distributor or to Isotecnic factory for a complete overhaul every 2 years or after 500 dives No reproduction in any...

Page 18: ...Via Milano 177 B Castelnuovo del Garda VR 37014 Verona Italy Tel 39 045 6450480 info isotecnic it www isotecnic it HOUSINGS and ACCESSORIES for UNDERWATER PHOTOGRAPHY Follow us on...

Reviews: