For connection to the TWIST module
5 x 0.5mm² cable 12 Vdc + line power supply / IR sensor presence detection / motor relay control
from terminal n ° 5 positive 12Vdc (brown color)> to terminal n ° 11 of the electrical panel inside the Twist
from negative 12Vdc terminal n ° 6 (black color)> to terminal n ° 12 of the electrical panel inside the Twist
from terminal n ° 7 12Vdc NC line contact (gray color)> to terminal n ° 13 of the electrical panel inside the Twist
from terminal n ° 8 12Vdc NC line contact (yellow / green color)> to terminal n ° 14 of the electrical panel inside the Twist
from terminal n ° 16 positive motor relay command> to terminal n ° 17 of the electrical panel inside the Twist
Terminal 15 on the electrical panel inside the TWIST is used as a support in case of connecting several products in series for the NC,
safety line.
For all the details relating to the connections and connections of the components, refer to the wiring diagrams shown below
Attention: the connection to the electrical network must only be carried out by technical personnel with the necessary skills
•
on certified plants equipped with a declaration of conformity,
•
on systems protected with a 6A differential magnetothermic switch
Before activating the switch on the control console, make sure that:
- the data of the power line correspond to those of the appliance itself
- the lamps have been fitted correctly
- all components and accessories are correctly placed in their place
WARNING!
IT IS STRICTLY FORBIDDEN TO TAMPER WITH THE PRESENCE DETECTION SENSORS AS IT COM-
PROMISES THE SAFETY OF PEOPLE AND ANIMALS.
Passage for IN and OUT con-
nections on the control console
Wall-mounted electrical panel for control console
F
2
3
4
5
6
7
8
hour counter
230Vac-12Vdc power supply
Relè lampade
16
Exit time selection
timer
1
N
Block relay
safety