HTSPRT Model 96178 Iss.06 – 03/11 

GUARANTEE 

 

 

This instrument has been manufactured to exacting standards and is guaranteed for twelve months against electrical 

break-down or mechanical failure caused through defective material or workmanship, provided the failure is not the 

result of misuse.  In the event of failure covered by this guarantee, the instrument must be returned, carriage paid, to 

the supplier for examination and will be replaced or repaired at our option. 

 

FRAGILE CERAMIC AND/OR GLASS PARTS ARE NOT COVERED BY THIS GUARANTEE 

 

INTERFERENCE WITH OR FAILURE TO PROPERLY MAINTAIN THIS INSTRUMENT MAY INVALIDATE THIS 

GUARANTEE 

 

RECOMMENDATION

 

 

The life of your 

ISOTECH

 Instrument will be prolonged if regular maintenance and cleaning to remove general dust 

and debris is carried out. 

 

 

ISOTHERMAL TECHNOLOGY LTD. 

PINE GROVE, SOUTHPORT 

PR9 9AG, ENGLAND 

 

TEL: +44 (0) 1704 543830/544611 

FAX: +44 (0)1704) 544799 

 

The company is always willing to give technical advice and assistance where appropriate.  Equally, because of the 

programme of continual development and improvement we reserve the right to amend or alter characteristics and 

design without prior notice.  This publication is for information only. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

Summary of Contents for 96178

Page 1: ...PR9 9AG England Tel 44 0 1704 543830 Fax 44 0 1704 544799 Internet www isotech co uk E mail info isotech co uk The company is always willing to give technical advice and assistance where appropriate E...

Page 2: ...TO ISOTECH 4 Preparing the box 5 STABILITY EVALUATION 6 INTRODUCTION 6 METHOD 6 RESULTS 7 DISCUSSION OF RESULTS 7 CONCLUSION 8 FURTHER WORK 8 GLOSSARY OF METROLOGICAL TERMS 11 ACCURACY OF MEASUREMENT...

Page 3: ...GLASS PARTS ARE NOT COVERED BY THIS GUARANTEE INTERFERENCE WITH OR FAILURE TO PROPERLY MAINTAIN THIS INSTRUMENT MAY INVALIDATE THIS GUARANTEE RECOMMENDATION The life of your ISOTECH Instrument will b...

Page 4: ...8 and keep the gloves clean 6 Quartz is glass It is a supercooled liquid At 800 C and above your 96178 will bend and bow if you do not support it along its complete length At high temperatures I recom...

Page 5: ...from moving seal the box lower it into the outer box and fill with chips then lift the inner box slightly so the polystyrene chips completely surround it Place the protective sheath if supplied on to...

Page 6: ...thermometers will change its characteristics if subjected to step changes of temperature The way in which the thermometer is temperature cycled is therefore very important In this series of tests the...

Page 7: ...ure even so the stability of the new thermometer is remarkable There is always an initial shift in the characteristics of a high temperature thermometer during its first cycle to the silver point In t...

Page 8: ...e Uncertainties vary depending on the temperature range of calibration Isotech s Models 670H and 96178 Standard Platinum Resistance Thermometers SPRT s can be calibrated using procedural techniques ai...

Page 9: ...Page 9 of 12 HTSPRT Model 96178 Iss 06 03 11...

Page 10: ...Page 10 of 12 HTSPRT Model 96178 Iss 06 03 11...

Page 11: ...2 Reproducibility may be expressed quantitatively in terms of the dispersion of the results UNCERTAINTY OF MEASUREMENT An estimate characterising the range of values within which the true value of a...

Page 12: ...Page 12 of 12 HTSPRT Model 96178 Iss 06 03 11 PACKING INSTRUCTIONS FOR THE RETURN OF YOUR 96178...

Reviews: