3
Power connection
This unit provides 4 pin terminal block. It can be operated using either VAC or VDC power source. The VDC
power range is from 12VDC to 56VDC, and the VAC power range is from 18VAC to 36VAC. Always Make
sure your input voltage is within this supported voltage range.
WARNING – any exceeded input voltage will not make this unit function and may damage this unit.
To make power connection – Follow the printed polarity for V+, V-, Ground. Connect positive wire to V+ ,
connect negative wire to V-, also connect neutral wire to ground.
Connecting procedure
STEP 1 –
Take out 4 pin terminal block located in the included mounting kit package.
STEP 2 –
connect power wire to 4 pin terminal block. V1+, V1- or redundant power wire to V2 + V2-. and Ground
STEP 3 –
Plug into terminal block socket shown above. Polarity needs to match the V+ and V-
WARNING -- Always SHUTS OFF power source to connect power wire.
+ V1 - + V2 -
Din Rail Bracket x 1
Wall mount bracket x 2
4 pin Terminal Block x1
Installation package
This unit can be installed by din-rail mounted or wall-mounted. Din-rail brackets and wall-mounted bracket
are included.
Summary of Contents for IS-DG102-F
Page 7: ...7 Housing Dimension...