background image

6G

  4. DMX Link & Controls   

 

1.  DMX output: 

pin 1: Comm., pin 2: DMX

, pin 3: DMX

.   

2.  DMX input: 

pin 1: comm., pin 2: DMX

, pin 3: DMX

.    If you are using a controller with 

5 pins DMX output, you will need to use a 5 to 3 pin adapter. 

3.  Dipswitch: 

Dipswitch 1-9 set the DMX channel that the unit will respond to. Channel 1 is 

the start address.    Switch 10 sets the master/slave in 

group

 of all the units.    Please 

refer to the diagram on setting the dipswitches. 

4.  Red LED: DMX signal / Sound activation. 

  This LED will flash when DMX signal is 

being received or sound activation is working. 

5.  Built-in microphone for sound activation.

 

        Connect the unit together in a 

daisy chain

 by XLR plug from the output of the unit to the 

input of the next unit.    The cable can not be branched or split to a 

Y

 cable.    DMX512 is 

a very high-speed signal. Inadequate or damaged cables solder joints or corroded 

connectors can easily distort the signal and shut down the system. 

 

 

 

 

  5. How To Control The Unit 

   

 

        You can operate the unit in four ways: 

A. By master/slave preprogrammed function 

      By linking the units in master/slave connection, 

the first unit will control the other units to give an 

automatic activated synchronized light show.    In this 

mode, the first unit

master

dipswitch 10 must be on.   

This function is good when you want an instant show.    You will know which unit is the master 

because its DMX input jack will have nothing plugged into it and its red LED will flash to the 

music.    The other units (slaves) will have DMX cables plugged into the DMX input jacks 

(daisy chain) and the red LED lights will be constantly flashing. Please refer to the diagram 

on setting the dipswitches. 

 

B. By easy controller(CA-8 & CA-8F) 

The  easy  remote  control is used  only in master/slave mode.  By connecting to the  1/4

 

microphone  jack  of  the  first  unit,  you  will  find  that  the  remote  control  on  the  first  unit  will 

control all the other units for Stand by, Function/Mode.   

 

 

 

 

 

     

 

           

Stand By 

Blackout the unit 

Function 

1.  Synchronous Strobe 
2.  2-light Show Strobe 

Full on/Color select 
 

Dimmer 

Mode 

Sound 

Manual 

Latch 

 

Channel  Dip switches setting 

Master   

 

Slave 1 

ON

10

9

8

7

6

5

4

3

2

1

 

Slave 2 

ON

10

9

8

7

6

5

4

3

2

1

 

Slave 3 

4

ON

2

1

3

5

7

6

8 9 10

 

Summary of Contents for iColor 3

Page 1: ...User Guide Professional Entertainment Technology...

Page 2: ...2G...

Page 3: ...ns 2 Main Features 3 Lamp 4 DMX Linking Controls 5 How To Control The Unit A By master slave preprogrammed function B By easy controller C By Colormix controller D By universal DMX controller 6 Troubl...

Page 4: ...from the walls and at least 100 cm from adjacent surfaces Be sure than no ventilation slots are blocked Be careful that no liquids or other objects can enter the unit If this ever happens disconnect t...

Page 5: ...ddress By DMX linking and XLR cable This units can be linked together in a master slave combination and run by built in programs Compatible with easy controller or universal DMX controller DMX signal...

Page 6: ...all the units Please refer to the diagram on setting the dipswitches 4 Red LED DMX signal Sound activation This LED will flash when DMX signal is being received or sound activation is working 5 Built...

Page 7: ...r units slaves will have DMX cables plugged into the DMX input jacks daisy chain and the red LED lights will be constantly flashing Please refer to the diagram on setting the dipswitches B By easy con...

Page 8: ...ent chase patterns Providing the richest changing colors for the show Speed and dimmer adjustable for both color fade and chase Sound activated function is available Full on and Blackout functions CA...

Page 9: ...MX512 system in the binary code DMX512 Address Chart Dip 1 2 3 4 5 6 7 8 9 10 Value 1 2 4 8 16 32 64 128 256 M S Examples Channel 1 dip on 1 1 Channel 5 dip on 1 3 1 4 5 Channel 9 dip on 1 4 1 8 9 Cha...

Page 10: ...nal problems check the pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that...

Page 11: ...carefully Clean the external optics at least once every 20 days Clean the internal optics at least every 30 60 days EC Declaration of Conformity We declare that our products lighting equipments compl...

Page 12: ...C 230 240 250V 50 60Hz Fuse 6X30mm Glass T15A Lamps J Type 120V 300W J Type 230V 500W Dimension 360mm x 225mm x 150mm i Color 3 450mm x 270mm x 175mm i Color 4 Weight 6 kg 13 2 lbs i Color 3 7 kg 15 4...