background image

 

2- 

1. Safety Instruction 

 

 

 

WARNING

 

y

  Please keep this User Guide for future consultation. If you sell the unit to another user, be 

sure that they also receive this instruction booklet. 

y

  Unpack and check carefully there is no transportation damage before using the unit. 

y

  Before operating, ensure that the voltage and frequency of power supply match the power 

requirements of the unit.   

y

  The unit is designed for use with the HID 150W or ELC 250W (two version). Do not use 

any other type of lamp.   

y

  It’s  important  to  ground  the  yellow/green  conductor  to  earth  in  order  to  avoid  electric 

shock. 

y

  The unit is for indoor use only. Use only in a dry location. 

y

  The  unit  must  be  installed  in  a  location  with  adequate  ventilation,  at  least  50cm  from 

adjacent surfaces. Be sure that no ventilation slots are blocked.   

y

  Disconnect main power before fuse/lamp replacement or servicing.   

y

  Replace fuse/lamp only with the same type.   

y

  Make  sure there  is no  flammable materials close  to  the  unit  while operating  as it is fire 

hazard.   

y

  Use  safety  cable  when fixes  this unit.  Don’t  handle the  unit by  taking  its head  only,  but 

always by taking its base.     

y

  Maximum  ambient  temperature  is  TA:  40

.  Don’t  operate  it  where  the  temperature  is 

higher than this. 

y

  Unit surface temperature may reach up to 85

. Don’t touch the housing bare-hand during 

its  operation.  Turn  off  the  power  and  allow  about  15  minutes  for  the  unit  to  cool  down 

before replacing bulb or serving. 

y

  In  the  event  of serious operating  problem,  stop  using the  unit immediately.  Never  try  to 

repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or 

malfunction.  Please  contact  the  nearest  authorized  technical  assistance  center.  Always 

use the same type spare parts.     

y

  Don’t connect the device to any dimmer pack or power pack. 

y

  Do not touch any wire during operation as high voltage might be causing electric shock. 

Please read carefully the instruction, which includes important information 

about the installation, usage and maintenance. 

 

3- 

Warning 

y

  To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or 

moisture. 

y

  Never touch bulb with bare fingers as it is very hot after using.   

y

  Hot lamp explosion hazard. Do not open the unit within five minutes after switching off.     

y

  Do not start on the unit without bulb enclosure or housing are damaged. 

y

  The  housing,  the  lenses,  or  the  ultraviolet  filter  must  be  replaced  if  they  are  visibly 

damaged. 

y

  Do not look directly at the light while the bulb is on.

 

Caution 

There are no user serviceable parts inside the unit. Do not open the housing or attempt 

any repairs yourself.  In the  unlikely  event your  unit may  require service,  please  contact 

your nearest dealer.

 

Installation 

The  unit  should  be mounted  via its screw  holes  on the  bracket.  Always  ensure that  the 

unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the 

structure to which you are attaching the unit is secure and is able to support a weight of 20 

kg for each unit. 

 

2. Technical Specification   

 Voltage

AC 100V//120V/230V/240V/250V 50/60Hz 

 Bulb

HID 150W 

 

ELC 250W   

 

The unit is DMX 512 fixture. It features full DMX 512 control. It can be

 also

 linked together 

in  master/slave  connection,  as  many  as  required  and  run  by  built-in  program  chase 

sequences automatically or by sound activation through an internal microphone to create 

an intelligent effect. 

  It  can  be  operated  by  DMX  512  control  or  can  be  used  as  an  individual  unit  without  a 

controller. 

 Features different preprogrammed chase patterns. 

 Please use a 3 pin XLR cable/plug when connecting 

units

 together. 

 

Accurate focusable optics system and ultra smooth stepping motors, Fan cooled.

 

 Pan: 540 deg. Tilt: 270 deg. 

 

Dimension: 266 x 276 x 370mm 

 Weight: 10 kg

 

Summary of Contents for iMove 200SR

Page 1: ...t Technology 1 TABLE OF CONTENTS 1 Safety Instruction 2 Technical Specification 3 Lamp 4 How To Set The Unit 5 How To Control The Unit 6 DMX512 Configuration 7 DMX512 Connection 8 Troubleshooting 9 Fi...

Page 2: ...pack or power pack y Do not touch any wire during operation as high voltage might be causing electric shock Please read carefully the instruction which includes important information about the instal...

Page 3: ...ce do not open the fixture within 15 minutes until the unit cools down after switching off 5 3 1 HID 150W Lamp Installation Or Replacement Always switch power off before installing or replacing the la...

Page 4: ...select any of the given functions press the MENU button up to when the required one is showing on the display Select the function by ENTER button and the display will blink Use DOWN and UP button to...

Page 5: ...ge after 8 seconds To go back to the functions without any change press the MENU button again 9 Blackout Mode Press the MENU button up to when the is showing on the display Pressing ENTER button and t...

Page 6: ...trol The Unit You can operate the unit in three ways 1 By master slave built in preprogram function 2 By easy controller 3 By iLead controller Please refer to the user guide of iLead or universal DMX...

Page 7: ...to 512 channel so that the units can receive DMX signal Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change...

Page 8: ...can not branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 4...

Page 9: ...e signal 2 Wrong DMX address in the unit Set the proper address D No response to the sound 1 Make sure the unit does not receive DMX signal 2 Check microphone to see if it is good by tapping the micro...

Page 10: ...ean the external optics at least every 20 days Clean the internal optics at least every 30 60 days EC Declaration of Conformity We declare that our products lighting equipments comply with the followi...