7E

 3. Lamp  

 

 

 

Because of its high internal pressure, there might be a risk that the Discharge lamp 

would explode during operation. The lamp emits intense UV radiation which is harmful to 

the eyes and skin. The high luminance of the arc can cause severe damage to the retina 

if looks directly at the lamp. 

 

    Discharge lamp : MSD 250/2 (IM-8S) 

                                HTI 150W (IM-7S) 

1. Always switch off the main supply and never handle 

the lamp or luminaries when is hot. 

2. Do not touch the bulb with bare hands. If this 

happens, clean the lamp with denatured alcohol and 

wipe it with a lint free cloth before installation. 

3. The lamp generates UV radiation. Never operate the 

lamp without appropriate shielding. 

4. When burning, the lamp operates at high pressure and 

there is a slight risk of arc tube rupture. The risk 

increases with age, temperature and improper handling 

of the lamp. Do not use the lamp any longer than its 

specified life.   

5. Make sure the lamp is located in the center of the 

reflector for the best spot. Adjust lamp position by 

screws A, B and C. 

 

  5.5 DMX512 Connection 

 

The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels. 

 

1. If you use a controller with 5 pins DMX connector, you need to use a 5 to 3 pin adapter. 

2. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W 

resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the 

DMX-output of the last unit. 

3. Connect the unit together in a “daisy chain” by XLR plug from the output of the unit to the 

input of the next unit. The cable can not branched or split to a “Y” cable. DMX512 is a very 

high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors 

can easily distort the signal and shut down the system. 

4. The DMX output and input connectors are pass-through to maintain the DMX circuit, when 

power is disconnected to the unit. 

5. Each lighting unit needs to have an address set to receive the data sent by the controller. 

The address number is between 0-511 (usually 0 & 1 are equal to 1). 

6. The end of the DMX512 system should be terminated to reduce signal errors. 

7. 3 pin XLR connectors are more popular than 5 pins XLR. 

3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)   

5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 

 

 

In case of replacement of the lamp or maintenance, do not open the

  fixture within 15 minutes until the unit cools down after switching off.

IM-8S

IM-7S 

Summary of Contents for IM-7S

Page 1: ...Blow Lamp MSD 250 2 Dimension 360mm x 397mm x 503mm Weight 26 kg IM 7S Power AC 120V 60Hz or AC 230 240 250V 50 60Hz Fuse 20mm Glass T6 3A Fast Blow Lamp HTI 150W Dimension 373mm x 295mm x 451 mm Wei...

Page 2: ...following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN6100...

Page 3: ...o 85 Don t touch the housing bare hand during its operation Turn off the power and allow about 15 minutes for the unit to cool down before replacing bulb or serving In the event of serious operating p...

Page 4: ...nses or the ultraviolet filter must be replaced if they are visibly damaged Do not look directly at the light while the bulb is on Caution There are no user serviceable parts inside the unit Do not op...

Page 5: ...IM 7S Channel 1 Pan motion Pan motion Channel 2 Tilt motion Tilt motion Channel 3 Shutter Shaking Shutter Shaking Channel 4 Gobo Gobo Channel 5 Color Color Channel 6 Gobo Rotation Gobo Rotation Channe...

Page 6: ...2 Wrong DMX address in the unit Set the proper address D No response to the sound 1 Make sure the unit does not receive DMX signal 2 Check microphone to see if it is good by tapping the microphone E O...

Page 7: ...512 channels 1 If you use a controller with 5 pins DMX connector you need to use a 5 to 3 pin adapter 2 At last unit the DMX cable has to be terminated with a terminator Solder a 120 ohm 1 4W resisto...

Page 8: ...MENU To select the programming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions Remote controller input By co...

Page 9: ...strobe 3 Two light strobe X Y moving show mode selection Show 1 Show 4 Please refer to Show mode in 4 2 Main Function Color Gobo selection 1 Hold on for gobo change 2 Press shortly for color change X...

Page 10: ...l find that the remote control on the first unit will control all the other units for Stand by Function and Mode Show Mode Press the MENU button up to when the is showing on the display Pressing ENTER...

Page 11: ...Led Display Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the Led on or Led off mode Once the mode h...

Reviews: