background image

10C 

the functions without any change press the 

MENU

 button again.

 

  Show Mode 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 (show 1) 

or 

 (show 2) or 

 (show 3) or 

  (show 4) mode. Once the mode has 

been selected, press the 

ENTER

 button to setup or automatically return to the main 

functions without any change after 8 seconds. To go back to the functions without any 

change press the

 MENU

 button again.   

 

    Show 1 mode - Fixture is placed on the floor. Tilt movement angle 210°. 

    Show 2 mode - Fixture is fixed under ceiling. Tilt movement angle 90°. 

    Show 3 mode - Fixture is placed on the speaker, The spot is always projecting   

to the audience’s direction; i.e in front of the stage. Pan movement angle ( left to 

right to left ): 160°. Tilt movement angle: 90° ( 60° above horizon; 30° below horizon). 

  Show 4 mode - Fixture is fixed under ceiling. The spot is mainly projecting in front of 

the stage. Pan movement angle ( left to right to left ) :160°.    Tilt movement angle: 

90° ( vertically, front 75°; back 15° ) . 

 

   

Slave Mode 

 

Press the 

MENU

 button up to when the 

 

is shown on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 (normal) 

or 

 (2 light show) mode. Once the mode has been selected, press the 

ENTER

 

button to setup or automatically return to the main functions without any change after 8 

seconds. To go back to the functions without any change press the

 MENU

 button again. 

   

Blackout Mode

 

Press the 

MENU

 button up to when the 

 

is shown on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 (yes 

blackout) or 

 (no blackout) mode. Once the mode has been selected, press the 

ENTER

 button to setup or automatically return to the main functions without any change 

after 8 seconds. To go back to the functions without any change press the

 MENU

 button 

11C 

again. 

   

Pan Inversion

 

Press the 

MENU

 button up to when the 

 

is shown on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 (normal) 

or 

 (pan inversion) mode. Once the mode has been selected, press the 

ENTER

 

button to setup or automatically return to the main functions without any change after 8 

seconds. To go back to the functions without any change press the

 MENU

 button again. 

  Tilt Inversion

 

Press the 

MENU

 button up to when the 

 

is shown on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 (normal) 

or 

 (tilt inversion) mode. Once the mode has been selected, press the 

ENTER

 

button to setup or automatically return to the main functions without any change after 8 

seconds. To go back to the functions without any change press the

 MENU

 button again. 

  Led Display 

Press the 

MENU

 button up to when the 

 is showing on the display. Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to select the 

 

(Led on) or 

  (Led off) mode. Once the mode has been selected, press the 

ENTER

 

button to setup or automatically return to the main functions without any change after 8 

seconds. To go back to the functions without any change press the

 MENU

 button again. 

  Display Inversion

 

It is good for you to install the unit on the floor or under ceiling. Press the 

MENU

 button up to 

when the 

 

is blinking on the display. Use the 

ENTER

 button to change to the mode 

  (display inversion), It will automatically store after 8 seconds. Or press the 

ENTER

 

button again return to the mode 

  (display normal). To go back to the functions press 

the

 MENU

 button. 

   

Display normal mode for the fixture putting on the floor. 

   

Display inversion mode for the fixture fixing under ceiling. 

  Gobo1 focus Adjust 

Press the 

MENU

 button up to when the 

 

is blinking on the display. Pressing 

ENTER

 

Summary of Contents for DMX512 575W Plus

Page 1: ...cation 3 Lamp 4 How To Set The Unit 4 1 Control Panel 4 2 Main Function 4 3 Home Position Adjust 5 How To Control The Unit 5 1 Master Slave Built In Preprogrammed Function 5 2 Easy Controller 5 3 iSol...

Page 2: ...pairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts z Don t connect the devic...

Page 3: ...Gobo 2 Channel 2 Tilt Channel 10 Gobo 2 Rotation Channel 3 Pan Tilt Speed select Channel 11 Prism Channel 4 Dimmer Channel 12 Prism Rotation Channel 5 Shutter Shaking Channel 13 Focus Channel 6 Color...

Page 4: ...s If this happens clean the lamp with denatured alcohol and wipe it with a lint free cloth before installation 3 The lamp generates UV radiation Never operate the lamp without appropriate shielding 4...

Page 5: ...been selected press the ENTER button to setup or it will automatically return to the main functions without any change after idling 8 seconds To go back to the functions without any change press the M...

Page 6: ...n functions without any change after 8 seconds To go back to the functions without any change press the MENU button 11C again Pan Inversion Press the MENU button up to when the is shown on the display...

Page 7: ...and UP button to select the Lamp on or Lamp off mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds T...

Page 8: ...e use DOWN and UP button up to when the is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to adjust the gobo home position Once the gobo 1 has been select...

Page 9: ...e remote control on the first unit will control all the other units for Stand by Function and Mode 17C Stand by Blackout the unit Function Strobe 1 Color sync strobe 2 Sync strobe 3 Two light strobe X...

Page 10: ...ration i The value as below will be effected after about five seconds For DMX reset put DMX value of CH 16 to 200 209 For DMX lamp on put DMX value of CH 16 to 130 139 For DMX lamp off put DMX value o...

Page 11: ...occur during operation Here are some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connect power and main fuse 2 Measure the mains volta...

Page 12: ...screws G install the new belt and adjust the belt tension properly Note it is too tight to rupture 9 Plug all the connect wires back that form the bottom to the arm 10 Reverse the procedures from poin...

Page 13: ...screws and terminals have been locked firmly to make sure the normal performance of the fixtures Negligence of maintenance would cause malfunction of the fixture Cleaning The cleaning of internal and...

Page 14: ...ovision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harm...