background image

8C 

 DMX 

 On 

 DMX input present 

 MASTER   On 

 Master mode 

 SLAVE 

 On 

 Slave mode 

 SOUND 

 Flashing 

 Sound activation 

 

Button

 

  MENU 

  To select the programming functions 

  DOWN 

  To go backward in the selected functions 

  UP 

  To go forward in the selected functions 

  ENTER 

  To confirm the selected functions 

 

Remote controller input 

By connecting to the 1/4” microphone jack to control the unit for Stand by, Function, and 

Mode function. 

Sensitivity 

To adjust the sound-receiving sensitivity . 

DMX input/output 

For DMX 512 link, use 3-pin XLR plug cable to link the unit together. 

 

  4.2. Main Function   

To select any of the pre-set functions, press the 

MENU

 button up to when the required one 

is shown on the display. Select the function by 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button to change the mode. Once the required mode has been selected, 

press the 

ENTER

 button to setup or it will automatically return to the main functions without 

any change after idling 8 seconds. To go back to the functions without any change press the

 

MENU

 button. The main functions are shown below: 

9C 

 

   

DMX 512 Address Setting

 

Press the 

MENU

 button up to when the 

 

is shown on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 address.   

Once the address has been selected, press the 

ENTER

 button to setup or automatically 

return to the main functions without any change after 8 seconds. To go back to the functions   

without any change press the

 MENU

 button again. 

   

Channel Mode 

Press the 

MENU

 button up to when the 

 is shown on the display. 

Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 button 

to select the 

 (16 Channel ) or 

 (8 Channel) mode. Once the 

mode has been selected, press the 

ENTER

 button to setup or automatically 

return to the main functions without any change after 8 seconds. To go back to 

Summary of Contents for DMX512 575W Plus

Page 1: ...cation 3 Lamp 4 How To Set The Unit 4 1 Control Panel 4 2 Main Function 4 3 Home Position Adjust 5 How To Control The Unit 5 1 Master Slave Built In Preprogrammed Function 5 2 Easy Controller 5 3 iSol...

Page 2: ...pairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts z Don t connect the devic...

Page 3: ...Gobo 2 Channel 2 Tilt Channel 10 Gobo 2 Rotation Channel 3 Pan Tilt Speed select Channel 11 Prism Channel 4 Dimmer Channel 12 Prism Rotation Channel 5 Shutter Shaking Channel 13 Focus Channel 6 Color...

Page 4: ...s If this happens clean the lamp with denatured alcohol and wipe it with a lint free cloth before installation 3 The lamp generates UV radiation Never operate the lamp without appropriate shielding 4...

Page 5: ...been selected press the ENTER button to setup or it will automatically return to the main functions without any change after idling 8 seconds To go back to the functions without any change press the M...

Page 6: ...n functions without any change after 8 seconds To go back to the functions without any change press the MENU button 11C again Pan Inversion Press the MENU button up to when the is shown on the display...

Page 7: ...and UP button to select the Lamp on or Lamp off mode Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after 8 seconds T...

Page 8: ...e use DOWN and UP button up to when the is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to adjust the gobo home position Once the gobo 1 has been select...

Page 9: ...e remote control on the first unit will control all the other units for Stand by Function and Mode 17C Stand by Blackout the unit Function Strobe 1 Color sync strobe 2 Sync strobe 3 Two light strobe X...

Page 10: ...ration i The value as below will be effected after about five seconds For DMX reset put DMX value of CH 16 to 200 209 For DMX lamp on put DMX value of CH 16 to 130 139 For DMX lamp off put DMX value o...

Page 11: ...occur during operation Here are some suggestions for easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connect power and main fuse 2 Measure the mains volta...