![isobus TeeJet IC18 Oem Menu Setup Download Page 6](http://html1.mh-extra.com/html/isobus/teejet-ic18/teejet-ic18_oem-menu-setup_2093380006.webp)
4
www.teejet.com
IC18 Sprayer/NH3 OEM options
Valve Setup
Figure 1-8: Valve Setup - Sprayer Mode
Figure 1-9: Valve Setup - NH3 Mode
Figure 1-10: Tank Setup - Sprayer Mode
Figure 1-11: Tank Setup - NH3 Mode
Valve Setup establishes the Regulation Valve Type, Section Valve Type and
Section Valve Behavior.
Regulation Valve Type
Regulation Valve Type sets the vale type to either Throttle or Bypass.
•
To set the Regulation Valve Type, select an option from the drop down menu
or use the UP/DOWN ARROWS to highlight the option.
Section Valve Behavior
Section Valve Behavior sets the valve to either Independent or Follow Master.
•
To set the Section Valve Behavior, select an option from the drop down menu
or use the UP/DOWN ARROWS to highlight the option.
Section Valve Type (Sprayer Mode)
Section Valve Type sets the valve type to either 2-way or 3-way. Available only in
Sprayer and Turf Mode.
•
To set the Section Valve Type, select an option from the drop down menu or
use the UP/DOWN ARROWS to highlight the option.
Tank Setup
Tank Setup establishes maximum and minimum tank content, Auto Filling mode
and Auto Filling Offset value.
Maximum Content
Maximum Content establishes the maximum tank volume.
•
To set the Maximum Content, use the number pad or slide bar.
Minimum Content
Minimum Content establishes the minimum tank volume at which the tank agitation
should automatically be shut off.
•
To set the Minimum Content, use the number pad or slide bar.
Auto Filling (Sprayer Mode)
Auto Filling sets the automatic filling mode to either on or off. Available only in
Sprayer Mode.
•
To set the Auto Filling mode, select an option from the drop down menu or use
the UP/DOWN ARROWS to highlight the option.
Auto Filling Offset (Sprayer Mode)
Auto Filling Offset establishes the volume that will still run into the tank after the fill
valve has started shutting. Available only in Sprayer and Turf Mode.
•