3-5 Diode Check
1. Set the function switch at "
<
:
" position.
2. Connect the black test lead to the "COM" terminal and the red lead to "V
Ω
µA" input terminal.
3. Connect the test leads to the diode. Normally the forward voltage drop of a good silicon diode is between 400V
to .900V. If the diode under test is defective, "000" (short circuit) or "OL" (non-conductance) is displayed.
Reverse Check of Diode:
If the diode under test is good "1" is displayed. If the diode under test is defective "000"
or other values will be displayed.
3-6 Current Measurement
1. Set the function switch at "µA" position.
2. Connect black test lead to "COM" terminal and red lead to "V
Ω
µA" input terminal.
3. Connect the test leads to the circuit to be measured.