10
Range
Resolution
Accuracy (97)
Over voltage
300mV
10 µV
±(0.5% + 2D)
3V
1mV
30V
10mV
300V
100mV
600V
1V
600V d.c. or
600 V rms
Accuracy(97RMS)
±(0.4% + 2D)
Input Impedance : 10M
è
.
2.3 Electrical specification
Accuracy is given as ± (percentage of measurement error + displayed error) and applies at 23°C ± 5°C and less
than 75% RH. Measurement error (%) is given as a percentage of the current measurement.
Display error (D) is given in units equal to the smallest increment able to be shown on the display.