The DLA Series Style 2 Controller is a single circuit controller used to operate remotely located 12-vdc latching solenoids 
for domestic water services in a Drug Testing Laboratory. 
 
This unit is provided with ISIMET latching circuit boards that permit a 24-vac signal to latch the solenoids ON and OFF, 
controlling the water supply to the restroom facility. 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ISIMET     

 

         

DLA Controller    

Drug Testing Labs 

Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation, Operations, Start-up and 

Maintenance Instructions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table of Contents: 

 

Page 

Warranty………………………………………………….. 

Enclosure Specifications and Dimensions………………… 

Styles……………………………………………………… 

Model Number……………………………………………. 

Mounting Instructions (Flush)….…………………………. 

Mounting Instructions (Casework)..………………………. 

Mounting Instructions (Surface Mount)..…………………. 

Mounting the Wall Panel..………………………………… 

Circuit Output Configurations………………………….…. 

Monitoring Configurations………………………….…….. 

Installing the Electrical Conduit…………………………... 

Wiring the Unit……………………………………………. 

Wiring Configurations.. …………………………………… 

Operation of Unit………………………………………….. 

Equipment Maintenance…………………………………… 

 

October 2013 

Meets all Standards for Canadian Industrial Control Panels

 

Summary of Contents for DLA Series Style 2

Page 1: ...esting Labs Style 2 W Ver 4 41 pcb Pulse Relay pcb s Installation Operations Start up and Maintenance Instructions Table of Contents Page Warranty 2 Enclosure Specifications and Dimensions 3 Styles 3...

Page 2: ...period of two years from date of installation when installation complies with all start up and routine maintenance procedures and Start up has been performed by an authorized factory representative R...

Page 3: ...owder coated sheet metal 6 0 X 14 25 X 4 0 all dimensions are in inches Style Output Circuits Trans former Switch Breaker pcb Fuse 1 Output Rating standard Pulse Output DLA 2 1 24 vac 2 amp 5 amp 2 am...

Page 4: ...ening From within the cabinet fit into opening and fasten unit to back of casework Face of wall box should be even with face of cabinet After mounting unit protect interior of box from construction de...

Page 5: ...valves Connect both supply valves to pins 4 5 or Utilize when one 1 supply and one 1 drain down solenoid is provided Connect supply valve to pins 4 5 Connect drain down to pins 6 7 Figure 2 Utilized...

Page 6: ...n counter clockwise the two retaining clips at the top of the Panel and open Insert plug onto circuit header on PCB Turn Power ON Close the panel and lock CAUTION Do not install the panel until all wa...

Page 7: ...he piping system continues to function properly If you have any questions regarding the operation and maintenance of the DLA Controller please contact an ISIMET Service Representative The enclosure ha...

Page 8: ...logy ISIMET believes that sole and local authority means that the primary operator or the instructors should have the sole authority to start and stop the utility services within the immediate area of...

Reviews: