User Reference Manual – DuraPANEL 10.6”
PN: 08140-000 Rev A Page 5
2
General considerations on Installation and
Operation
The DuraPANEL 10.6” is designed to work at conditions according to IEC 60945. However,
keeping the temperature and vibration level at a minimum will extend the life time of the
product. ISIC recommend operating this product at normal room temperature (20-25 °C), with
the lowest level of vibration and humidity.
Installation of the DuraPANEL 10.6”
In order to obtain the best possible operating conditions, please note the following precautions.
-
When installing the DuraPANEL 10.6” always use original or identical fittings.
-
Room for cooling.
When designing the cabinet/console for the DuraPANEL 10.6”, please ensure that air
can flow freely around the cabinet, in order to avoid any unnecessary rise in
temperature. If it is not possible to have an adequate natural airflow, use a fan to
force the airflow to be higher.
-
Mounting positions
To obtain adequate cooling by convection ISIC recommends that the DuraPANEL
10.6” is mounted at least 30 degrees from horizontal. If this is not possible, forced
cooling must be applied directly to the unit in order not to overheat it.
-
Sunlight
Avoid direct sunlight to keep temperature low and by that improve lifetime.