20 - 25
point (remark NC/COM/NO) to other detectors or monitors for the application to stop
machine when the lubricant is insufficient.
After the electrical connection is finished, tighten the cable gland (Fig.9) and fix the
cover. Then turn on the power and the lubrication indicator light on the panel will lamp and
the motor feeds oil if the electrical connection is correct.
3. General information
3-1Control panel
Fig.10
3.2 Intermittence Time/ Lubrication Time Display
The setting of intermittent time and lubrication time can be adjusted by pressing any
of
”
▲
”
or
”
▼
”
for two seconds and read from value from the display. If no
further action, the timer will restart after 5 seconds.
Intermittence time display indicates the set value and the remaining of intermittent time
during the lubrication unit working. Lubrication time display indicates the set value and the
remaining of intermittent time during the lubrication unit working. When pressing any of
the
”
▲
”
and
”
▼
”
of Lubrication Time/ Intermittence Time for two seconds,
the set-up value will be shown. If no further action, the timer will restart after 2 seconds.
3.3 Intermittence Time/ Lubrication Time set up
Press any of
”
▲
”
or
”
▼
”
for two seconds and then enter time setting
mode by pressing
”
▲
”
or
”
▼
”
to adjust time from 1 to 999 for interval and
lubricating. Continuously press
”
▲
”
or
”
▼
”
to fast increase or decrease value.
During time setting mode, two indicators will spark in the same time.
Time unit for intermittence is minute ; Time unit for lubrication is second
Indicator light of LUB.(Yellow)
Display of INT. Time
Display of LUB. Time
Indicator light of INT. (Green)
Indicator light of alarm (Red)
Increase of LUB. time
Decrease of INT. time
Increase of INT. time
Decrease of LUB. time
RES (Feed pushbutton)