29
Product Version 1.0 | Revision A | Released 2022-2-21
LED ENGINE
The i-2 UVA LED engine is comprised of 365nm wavelength ultra-violet LEDs. Extra care should be taken to avoid pro
-
longed contact with UV light. Please refer to safety warnings at the beginning of this manual.
INDIVIDUAL FIXTURE SETTINGS
Setting the dimming curve
Setting the dimming curve will determine the fixture’s behaviour, when changing the light intensity between 0% -
100%.
Linear control provides uniform adjustment throughout the control action, whereas gamma corrected dimming pro
-
vides finer control at low light levels, where the eye is more sensitive to change. By default, the i-2 UVA uses gamma
corrected dimming. For a uniform response, set all fixtures to the same dimming curve.
Flipping the OLED display (POI n.a.)
If the fixture is installed hanging upside down, it might be useful to flip the display so that it is easier to read.
To flip the display, press ENTER and select SETTINGS → FLIP DISPLAY, or press the up and down buttons on the control
panel at the same time.
Setting the OLED display saver (POI n.a.)
By default the OLED display dims down after a short period when the control panel is not in use. The display can also
be set to turn off completely. Pressing any key will turn on the display or restore it to normal brightness.
To configure the display settings, press ENTER → SETTINGS → DISPLAY SAVER.
PLEASE NOTE! TO AVOID THE RISK OF DISPLAY DETERIORATION CAUSED BY LONG TERM USAGE, IT IS RECOM-
MENDED TO SELECT SETTINGS → DISPLAY OFF.
Setting the fan mode
For environments where low-noise is a requirement, or where the fixture will be operating in high temperatures, it is
possible to adjust the default fan speed by going to SETTINGS → FAN MODE in the menu. In POI versions, this is done
via RDM.
PLEASE NOTE! IN POI FIXTURES, FAN MODE ADJUSTMENT IS DONE THROUGH RDM.
FIXTURE PROPERTIES
FACTORY DEFAULT
•
When restoring the i-2 UVA to the factory defaults,
the following settings will be set:
•
DMX address = 1.
•
DMX mode = Default mode (6 channel).
•
Startup mode = DMX.
•
Display saver = Off.
•
Flip screen = Off.
•
RDM device label set to = Fixture type name.
•
Internal program reset.