![Iseo MDC IS9100 Mounting Instructions Download Page 11](http://html1.mh-extra.com/html/iseo/mdc-is9100/mdc-is9100_mounting-instructions_2092660011.webp)
IS9100
—
MDC
11
ISEO
A
A + 5mm
33
5. Linking both operators
Move the joint socket at the passive leaf towards
the operator.
Measure the clearance between the two joint sockets
(dimension
A).
Cut the threaded rod to length
A + 5 mm.
34
Fix the counter nut and the ball end loosely onto the
threaded rod (at the side where you cut it to length).
.
Clip the ball ends into the joint sockets.
First insert the preinstalled ball end into the joint socket at
the side of the active leaf, and then clip the other ball end
into the joint socket at the side of the passive leaf.
Length adjustment is realised by turning the rod.
A clearance of 1 - 2 mm is required between the collar of
the coupling bolt and the brake.
Open both door leaves and then trigger a closing cycle in
order to check if the passive door leaf remains in waiting
position.
Lock the coupling bolt with the aid of the nut.
37
Connect the enclosed linking cable to the two “horizontal”
connectors RJ45 on the control unit.
1 - 2 mm
36
2.
1.
35
Summary of Contents for MDC IS9100
Page 1: ...Mounting instructions IS9100 MDC ...
Page 15: ...Notice de pose IS9100 MDC ...