background image

WARNING!

WARNING!

The protective conductor connection must be ensured by an appropriate mains cable. Before connecting to the 
local power supply, check whether the nominal voltage of the devices corresponds to the mains voltage.

WARNING!

WARNING!

Risk of death due to electric shock!
Disconnect the appliance from the mains before carrying out any work. Do not open the housing of the unit!

WARNING!

WARNING!

The mains connection is made with basic insulation and protective conductor. The device may only be operated 
with the protective earth conductor (PE) connected!
The protective conductor connections must be checked for proper function after installation.

CAUTION!

CAUTION!

When installing the units, make sure that an air flow through the corresponding air inlet and outlet openings is 
possible.

INFORMATION

INFORMATION

Please check the compatibility with the devices used.

ECH 224 – 4 Slot MMS Crate | Last modified on: 25.05.2020  |  www.iseg-hv.com

6/14

Summary of Contents for ECH 224

Page 1: ...umentation last changed on 25 05 2020 ECH 224 4 Slot 19 MMS Crate Series for iseg MMS High Voltage Power Supply Modules up to 4 MMS High Voltage Power Supply Modules 300W wide range of HV modules integrated fan unit ...

Page 2: ... Spezialelektronik GmbH This information has been prepared for assisting operation and maintenance personnel to enable efficient use The information in this manual is subject to change without notice We take no responsibility for any mistake in the document We reserve the right to make changes in the product design without reservation and without notification to the users We decline all responsibi...

Page 3: ...y instructions DANGER DANGER Danger indicates a severe injury hazard The non observance of safety instructions marked as Danger will lead to possible injury or death WARNING WARNING Warning indicates an injury hazard The non observance of safety instructions marked as Warning could lead to possible injury or death CAUTION CAUTION Advices marked as Caution describe actions to avoid possible damages...

Page 4: ...sures on the basis of his technical training his knowledge and experience as well as his knowledge of the relevant regulations General safety instructions Observe the valid regulations for accident prevention and environmental protection Observe the safety regulations of the country in which the product is used Observe the technical data and environmental conditions specified in the product docume...

Page 5: ...allowed to open the unit There are no parts which can be maintained by users inside of the unit Opening the unit will void the warranty WARNING WARNING Before connecting or disconnecting HV cables or any operation on the HV output or the application the unit has to be switched off and discharge of residual voltage has to be finished Depending on application residual voltages can be present for lon...

Page 6: ...ng of the unit WARNING WARNING The mains connection is made with basic insulation and protective conductor The device may only be operated with the protective earth conductor PE connected The protective conductor connections must be checked for proper function after installation CAUTION CAUTION When installing the units make sure that an air flow through the corresponding air inlet and outlet open...

Page 7: ...structions 5 1 General information 8 2 Technical data 8 3 Operation and maintenance 9 3 1 Front panel 9 3 2 Bank select switch 10 3 3 Forced air cooling 10 4 Dimensional drawings 11 5 Connectors and PIN assignments 12 6 Accesories 12 7 Order guides 13 8 Appendix 13 9 Warranty Service 14 10 Disposal 14 11 Manufacturer contact 14 ECH 224 4 Slot MMS Crate Last modified on 25 05 2020 www iseg hv com 7...

Page 8: ...cial Crate Controller Slot 2 Technical data SPECIFICATIONS ECH 224 Slots 4 x MMS modules and 1 x MMS controller Rated AC mains input 100 264 VAC with PFC Fuse 5x20mm 6 3AT AC power connector IEC 320 C14T DC module supply voltages 24 V 5V DC output power 300 W Connection CAN Cooling Vertical integrated fans bottom airintake Operation temperature 0 50 C ambient without derating Storage temperature 2...

Page 9: ... connect the module SL to the current source in the crate If the module safety loop is active see the manual of the module removing the bridge during operation opening the loop then the output voltages on all channels are shut off without ramp and the corresponding bit in the Status module will be cancelled After the loop will be closed again the channels must be switched ON and a new set voltage ...

Page 10: ...rol Bank Select Bank Select Bank Select 00 01 02 03 04 05 06 07 08 09 0A 0B L0 R0 L1 Figure 2 Crate schematic 3 3 Forced air cooling The crate offers an internal forced air cooling with temperature dependent speed regulation by the crate controller The fresh air intake is on the bottom for propper ventilation it needs to be sure that the airflow is not blocked INFORMATION INFORMATION Further it is...

Page 11: ...4 Dimensional drawings Figure 3 Dimensions ECH 224 ECH 224 4 Slot MMS Crate Last modified on 25 05 2020 www iseg hv com 11 14 ...

Page 12: ... POWER SUPPLY SIDE CABLE SIDE Safety Loop LEMO Socket ERA 0S 302 CLL Connector FFA 0S 302 CLAC Z592312 Table 4 Part numbers 6 Accesories CAUTION CAUTION Only use genuine iseg parts like power cables CAN cables and terminators for stable and safe operation ACCESSORY ITEM ORDER ITEM CODE SHV coupler screw for RG58 Z590162 SHV coupler screw for 5kV Z592474 Lemo plug 2 pole without collet chuck SL Z59...

Page 13: ...dules one significante digits 4 4 Slot two significante digits exponent For Examle 032 3 102 W 300W not available 00 none Tabelle 6 Order guides 8 Appendix For more information please use the following download links This document http download iseg hv com SYSTEMS MMS EHS iseg_manual_ECH224_en pdf Iseg HV Modules https www iseg hv com ECH 224 4 Slot MMS Crate Last modified on 25 05 2020 www iseg h...

Page 14: ...support rma 10 Disposal INFORMATION INFORMATION All high voltage equipment and integrated components are largely made of recyclable materials Do not dispose the device with regular residual waste Please use the recycling and disposal facilities for electrical and electronic equipment available in your country 11 Manufacturer contact iseg Spezialelektronik GmbH Bautzner Landstr 23 01454 Radeberg OT...

Reviews: