5. SAFETY CONSIDERATIONS

Warning:

 Use of this unit in a manner other than specified in this manual may impair the pro-

tection of the unit and subject the user to a hazard. Do not attempt to operate if the unit shows 
visible damage. 

Cautions: 

This  unit  may  be  powered  from  85-264  Vac  with  the  worldwide  voltage  power  supply 
(Model QLS-1) or from 12-30 Vac or 10-48 Vdc (Model QLS-2). Verify that you have the 
proper model for the power to be used.    

The 85-264 Vac power connector (P1 Pins 1-3) is colored 

Green

 to differentiate it from 

other  input  and  output  connectors.  The  12-30  Vac  or  10-48  Vdc  power  connector  is 
colored 

Black

. This unit has no power switch. It will be in operation as soon as power is 

applied.    

To  avoid  dangers  of  electrocution  and/or  short  circuit,  do  not  attempt  to  open  the  case 
while the unit is under power 

To prevent an electrical or fire hazard, do not expose the unit to excessive moisture. Do 
not  operate  the  unit  in  the  presence  of  flammable  gases  or  fumes,  as  such  an  environ-
ment constitutes an explosion hazard. 

Symbols used: 

Caution (refer to accompanying documents)    

Earth ground    

Caution, risk of electric shock    

Signal or loop ground    

Equipment protected throughout by double 
insulation or reinforced insulation.    

Both direct and alternating current.    

Operating environment: 

Class II (double insulated) equipment designed for use in Pollution degree 2.    

Summary of Contents for QLS-1

Page 1: ...d Output 4 20 mA Current Loop Splitter Retransmitter With 10V common mode isolation between input outputs ISE Inc 10100 Royalton Rd Cleveland OH 44133 USA Tel 440 237 3200 Fax 440 237 1744 Website ISE...

Page 2: ...loop loose their 4 20 mA signal The transmitter voltage compliance limit may be exceeded since the voltage drops across loads in series are additive Also the 4 20 mA signal to each load device cannot...

Page 3: ...48 Vdc power connector is colored Black This unit has no power switch It will be in operation as soon as power is applied To avoid dangers of electrocution and or short circuit do not attempt to open...

Page 4: ...al input connector on the circuit board The factory default input setting is 4 20 mA To change jumpers remove power then open the case by removing the screws at the four corners of the case Store the...

Page 5: ...y tied to signal ground SG which can be floating or be connected to earth ground Grounded loads Any output load R can be connected to a local loop ground LG instead of current return The loop grounds...

Page 6: ...marked Z for zero and S for span on the front panel The unit is factory jumpered and calibrated so that 4 20 mA in produces 4 20 mA out on all output channels To set or calibrate an output channel app...

Page 7: ...error at 23 C Span Tempco 10 ppm C 0 16 A C typical 25 ppm C 0 4 A C max AC Rejection 90 dB from DC to 60 Hz Response Speed 2 ms risetime 7 ms settling time to 0 1 of final value Current Test Point 10...

Page 8: ...Mishandling or abuse The warranty set forth above is exclusive and no other warranty whether written or oral is expressed or implied Laurel specifically disclaims implied warranties of merchantabilit...

Reviews: