background image

08

How to Confirm Charging Current

It is very important to know the maximum charging current of the battery as excessive 
current could influence the life span of battery and/or cause damages. In addition, exces-
sive current can cause heating and/or explosion of the battery during the charging 
process. 

The charging and discharging capacity of battery is usually marked with C value. Multiply-
ing the charging C value and battery capacity equals to the maximum charging current 
supported by the battery. For example, for a 1000 mAh battery with a charging capacity of 
5C, the maximum charging current would be 1000*5=5000mA; therefore, the maximum 
charging current is 5A. 

For a lithium battery, if it is impossible to confirm the supported charging C value, please 
set the charging current below 1C for the sake of its (lithium battery) safety. 

The reference relation between C value and charging time: charging time ≥60 minutes/ 
charging C value (it therefore needs around 60~70 minutes to complete charging with 1C). 
Due to differences in battery conversion efficiency, the period to complete the charging 
might be extended. 

Summary of Contents for D2 Smart Charger

Page 1: ...D2 Smart Charger Operating Instructions Ver 1 1 1706 ...

Page 2: ...functions of this smart charger as well as purchase various accessories Functions of products will be kept on upgrading the manual in your hand may be different from the actual operation please refer to the actual functions This user guide update date is June 20 2017 Innovative reform Friendly to use Revolution Starts Here ...

Page 3: ...ts Warnings and Safety Tips Product Parameters and Characteristics Default Battery Type of Charger and Task Parameters How to Confirm Charging Current Task Setting Operative Skills Working Parameters Display System Default Troubleshoot ...

Page 4: ...hile in use and ensure the cooling fan smoothly extracts heat Please fully understand the charging and discharging characteristics as well as the battery s specifications Additionally set up proper charging parameters in the charger Incorrect setting of parameters can cause damage to the charger and battery and or result to disastrous consequences such as fire or explosion Make sure input voltage ...

Page 5: ... can know more about relevant information of IDST products by following this link www isdt co 1 AC input 2 USB port 3 Update port 4 Balance port for channel 1 5 Battery port for channel 1 6 Battery port for channel 2 7 Balance port for channel 2 8 Channel 1 select button 9 Channel 2 select button 10 2 4 IPS display 11 Speed shuttle key 2 3 1 4 10 11 8 9 5 6 7 ...

Page 6: ...rature Storage Temperature Dimensions Weight LiFe Lilon LiPo LiHv 1 6S NiMH Cd 1 16S Pb 1 12S 2 4 320x240 IPS LCD 0 40 C 20 60 C 120x108x70 mm 510g AC 100 240V 0 1 12 0A 2 0 1 3 0A 2 200W 5W 2 1A cell 2 1 6S 2 Input Voltage Charge Current Discharge Current Max Charge Power Max Discharge Power Balance Current Balance Cells ...

Page 7: ...1 90V 1 80V Not supported supported 1 12S 12 0A 3 20V 3 65V 3 30V 2 90V 2 60V supported supported 1 6S 12 0A 3 60V 4 10V 3 70V 3 20V 2 90V supported supported 1 6S 12 0A Please be cautious when selecting the charging parameters for different types of batter ies otherwise the batteries may be damaged Incorrect setting can result to fire and or explosion 3 70V 4 20V 3 80V 3 30V 3 00V supported suppo...

Page 8: ...ximum charging current supported by the battery For example for a 1000 mAh battery with a charging capacity of 5C the maximum charging current would be 1000 5 5000mA therefore the maximum charging current is 5A For a lithium battery if it is impossible to confirm the supported charging C value please set the charging current below 1C for the sake of its lithium battery safety The reference relatio...

Page 9: ... as follows Task Battery type Cells voltage Cells count Current setting Start task Back Select task contents Charge Discharge Storage Select battery types End voltage slight adjustment range 0 05V Select batteries strings and the item processes automatic test and needs no setting if inserted in balanced interface Select current charge 0 1 12 A discharge storage 0 1 3 0 A Start to execute tasks bac...

Page 10: ...anced interface should be connected to carry out balanced charging to accurately monitor the voltage of each cell and balance the ones with bad consistency If battery voltage is lower than storage voltage charger will charge battery to storage voltage If battery voltage is higher than storage voltage charger will discharge battery to storage voltage In order to save storage time battery might not ...

Page 11: ...rging The charger should continue to balance the battery if the charging process is not terminated and the screen light turns blue since the voltage difference is smaller than 10mV Additionally the charger should continue to carry out accurate balancing of the battery after the light turns blue If the consistency of the cells is excellent the screen light should skip color green to become blue as ...

Page 12: ...can reach 200w both channels simultaneously initiate task would get 100w for each both channels non simultaneous initiate task the channel which initiate later will get 150w if task needs less than150w remaining power will go into the other channel automatically During dual Charging operation current adjust in a channel will get that channel 150w priority if task needs less than 150w remaining pow...

Page 13: ...nt operation or to enter setting menu for corresponding channel 3 While two batteries are the same type and same cells complete charging setting press both select button simultaneously to initiate task Both channels operate under sameparameters and would be assigned 50 50 from total power Operative Skills Speed Shuttle Select Button ...

Page 14: ... cell internal resistance and working parameter The cell voltage and internal resistance can only be displayed in the mode of balance charging 3 minutes Fast Charging Working Parameters Display Current channel Capacity charged Present current Battery type string number Current task status Device Name Task operation time Cell voltage ...

Page 15: ... Time Fast charging complete Capacity Charged Present Current Battery parameters Operation Status Name of your Q6 output voltage power operating temperature Finished charging PCs of batteries after boot Finished charging PCs of batteries in grand total Operation Time Precise Balance Charging Working Parameters Display ...

Page 16: ...lume Completion Tone Split Display Language Firmware Sharing System Information System Self checking Back Backlight adjustment High Middle Low and Auto Buzzer volume adjustment High Middle Low OFF Completion Tone Single time and Repeatable time Main page dual channel disaplay Manual and Auto System language setting share firmware with another device System information Firmly version System self ch...

Page 17: ...ormal battery connection pull out and plug in the battery again to ensure all connections are reliably contacted if the error reminder continues please check whether the metal parts on the battery interface are oxidized or burned resulting in unreliable connection 17 For electronic products with this marking in their manuals please separately dispose them with family garbage When a charger gets sp...

Page 18: ...ogy CO LTD WWW ISDT CO Changes in specifications and data will not be further noticed Address Rm 302 Building 11th Pingshan Creative Industry Park Pingshan 1 Road Nanshan District Shenzhen PRC Email hi isdt c Manufacturer ...