1.5)  OPERATION PARAMETER SETTING MENU 
 

WARNING: PERFORM THIS PROCEDURE ONLY AFTER HAVING READ THE 
FOLLOWING INSTRUCTIONS CAREFULLY. IF NOT PERFORMED PROPERLY, THIS 
PROCEDURE CAN CAUSE MALFUNCTIONING AND DAMAGE THE UNIT. 
 

Set menu 

0567

 (see chap. 1.1),confirm with the 

S

 Key. 

 
Press the 

F

 key repeatedly to select the following operation parameters in sequence: 

 

CODE 

VALUE 

P-t02 

60 

P-t03 

180 

P-t04 

60 

P-t05 

45 

P-t06 

04 

P-t07 

05 

P-t08 

02 

P-t09 

60 

P-t10 

00 

P-t11 

09 

P-t12 

60 

P-t13 

05 

P-t14 

240 

P-t15 

05 

P-udL 

0.700 

P-udH 

1.400 

P-ud1 

0.120 

P--Fd 

1.000 

rES 

 

P--Lb 

10.000 

t--AL 

3600 

 
When the display shows 

u---F

, the pressure transducer can be calibrated. 

Disconnect the quick connectors from the high and low pressure hoses. 
Open the 

LP-HP

 valves on the control panel to connect the pressure transducer to the 

atmospheric pressure. 
With the display showing 

u---F

, confirm with the 

S

 key. 

The display shows the theorical weight measured. 
Digit the value 

0.960

. Confirm with the 

S

 key. 

 
 
 
 
 

Summary of Contents for Tronic

Page 1: ...T 1 4 COMPONENTS AND FUNCTIONS TEST MENU 1 5 OPERATION PARAMETERS SETTING MENU 1 6 TABLE OF COMPONENT CODES 2 0 LIST OF COMPONENTS VIEW 2 1 GENERAL OVERVIEW 2 2 CONTROL PANEL VIEW 2 3 REAR VIEW 2 4 RE...

Page 2: ...available Stand by mode proceed as described below Press the UP Key and keep it pressed Press the S Key and keep it pressed Release the UP Key Press the DOWN Key and keep it pressed Release the S Key...

Page 3: ...hoses from the internal container 34 Set menu 0001 see Chap 1 1 confirm with the S Key The display shows P 0 With the scale plate 18 completely empty press the S Key The display shows P F Position th...

Page 4: ...the S Key The display shows cont Press the S Key The display shows the work time maximum time of 3600 Press the S Key and keep it pressed The display shows cont rESEt alternately When the display show...

Page 5: ...be selected sequentially Test 1 All display segments check Test 2 All leds check Test 4 Out C and keys check Test 5 Refrigerant scale net weight visualization Test 6 Pressure transducer visualization...

Page 6: ...VALUE P t02 60 P t03 180 P t04 60 P t05 45 P t06 04 P t07 05 P t08 02 P t09 60 P t10 00 P t11 09 P t12 60 P t13 05 P t14 240 P t15 05 P udL 0 700 P udH 1 400 P ud1 0 120 P Fd 1 000 rES P Lb 10 000 t...

Page 7: ...Fd 00 700 End OUT Use the F key to select the desired parameter and confirm by pressing the S key Use the UP DOWN keys to set the value shown in the table Confirm with the S key Select the parameter E...

Page 8: ...AD CELL 20 21 OIL INJECTION DRAIN CONTAINER 22 EXPANSION VALVE 25 500mm STRAIGHT STRAIGHT HOSE 26 500 mm 90 STRAIGHT HOSE 27 FAN CONDENSER 28 HP PRESSURE SWITCH 29 PROTECTION WIRE 30 500 mm 90 STRAIGH...

Page 9: ...Rev 0128 01 TRONIC SERVICE MANUAL SYSTEMS 9 2 0 LIST OF COMPONENTS VIEW 2 1 GENERAL OVERVIEW Picture 1 41 40 43 OPTIONAL 20 1 21 48 46 4 10 11 3 8 6 7 5 45 47...

Page 10: ...Rev 0128 01 TRONIC SERVICE MANUAL SYSTEMS 10 2 2 CONTROL PANEL VIEW Picture 2 10 11 S LED S DOWN UP LED G LED T LED W LED P LED C LED D LED B LED A LED F F 3 4...

Page 11: ...Rev 0128 01 TRONIC SERVICE MANUAL SYSTEMS 11 2 3 REAR VIEW Picture 3 42 2 49...

Page 12: ...Rev 0128 01 TRONIC SERVICE MANUAL SYSTEMS 12 2 4 REFRIGERANT CONTAINER SAFETY VALVES Picture 4 31 53 33 34 25 39...

Page 13: ...Rev 0128 01 TRONIC SERVICE MANUAL SYSTEMS 13 2 5 FRONT PART INSIDE VIEW Picture 5 29 22 28 30 25 34 18 17 16 27 65 15 13 14 39...

Page 14: ...IEW Picture 6 POS NAME DESCRIPTION 61A OUT B SOLENOID VALVE 4 5 mm 61B OUT B SOLENOID VALVE 4 5 mm 62A OUT A SOLENOID VALVE 3mm 62B OUT A SOLENOID VALVE 4 5 mm 63 OUT R SOLENOID VALVE 2 5 mm 64 OUT L...

Page 15: ...Rev 0128 01 TRONIC SERVICE MANUAL SYSTEMS 15 2 7 POWER BOARD VIEW Picture 7 71 81 80 72 74 75 76 73 79 78 77 70...

Page 16: ...Rev 0128 01 TRONIC SERVICE MANUAL SYSTEMS 16 2 8 LOGIC BOARD VIEW Picture 8 82 83 85 84...

Page 17: ...Rev 0128 01 TRONIC SERVICE MANUAL SYSTEMS 17 2 9 FLOW DIAGRAM...

Page 18: ...Rev 0128 01 TRONIC SERVICE MANUAL SYSTEMS 18 2 10 ELECTRICAL DIAGRAM...

Page 19: ...RE SWITCH INPUT PRESSURE SWITCH 28 7 73 COMPRESS 3 POWER COMP OUT C COMPRESSOR 16 7 74 PUMP 3 POWER PUMP OUT P VACUUM PUMP 17 7 75 PUMP 3 POWER VACUUM SV OUT B OUT B 7 76 OUT 1 3 POWER RECOVERY SV OUT...

Page 20: ...Rev 0128 01 TRONIC SERVICE MANUAL SYSTEMS 20 CONTROL PANEL S F UP DOWN...

Reviews: