2.5.3 Reset / EDM setting
Fig.2.5.3.1 Reset / EDM setting
[
Reset/EDM
]
tab is used to configure the reset mode and external device monitoring (EDM) function, as
shown in Fig.2.5.3.1.
For the specific meaning of
Manual
reset and
Auto
reset, and
EDM
function, please refer to the relevant
chapter of the
LSPD Safety Laser Scanner Operation Manual.
2.5.4 Field activation
Reminder:
Field is the same meaning with area group in the
LSPD Safety Laser Scanner Operation Manual
.
A field consists of one protective field (
protective area
) and one warning field (
warning area
).
Fig.2.5.4.1 Field activation tab
Setting areas includes the selection of four fields and definition of the external input signal (Z1, Z2, Z3 and
Z4).
LSPD can configure four fields at most. Each field consists of a protective field (maximum radius of 4 meters)
and a warning field (maximum radius of 15 meters).
When a field is checked, it is activated and can be edited in
[
Field activation
]
tab;
Otherwise, this field is disabled and the corresponding position is grayed out, this field can not be edited.