18
USE AND MAINTENANCE MANUAL
EN
428000467237
MILLENNIUM
9.
MAINTENANCE
The
Staff in charge of the appliance
must control and respect the expiry dates for maintenance, given in the table
below, contacting the authorised
Technical After-sales assistance
when indicated.
OPERATION
FREQUENCY
ORDINAR
Y
EXTRAORDINAR
Y
PERSONNEL
AUTHORISED
D
epending o
n the
Use an
d Necessit
y
Monthly
Ev
er
y 6
m
onths
An
nual
CLEANING THE EXTERNAL SURFACES
X
X
USER
CLEANING THE ACCESSIBLE INTERNAL PARTS
(without the use of tools)
X
X
CONTROL POWER SUPPLY CABLE,
PLUGS AND / OR ELECTRICAL SOCKETS
X
X
INTEGRITY CONTROL SEAL
X
X
FILTER CLEANING CONDENSING UNIT
(whenever present)
X
X
CLEANING THE DEFROSTING WATER COLLECTION TRAY
X
X
TECHNICAL
ASSISTANCE
CONDENSER CLEANING
X
X
X
CHECK COMPRESSOR OIL LEVEL
(whenever present)
X
AIR TANK DRAINING
(whenever present)
X
X
CONTROL PNEUMATIC CONNECTIONS
(whenever present)
X
X
INTEGRITY CONTROL PIPE COOLING SYSTEM
X
X
INSPECTION OF CABLES
INTERNAL CONNECTIONS AND POWER
X
X
CLEANING CONDENSATE DRYING SPONGES
(whenever present)
X
X
LAMP / LED REPLACEMENT
(whenever present)
X
CONTROL PANEL REPLACING
(electronic control unit - thermostat - etc.)
X
REPLACEMENT POWER SUPPLY CABLE, PLUGS AND / OR ELECTRICAL SOCKETS
X
ATTENTION
After all maintenance it is
mandatory
to perform all electrical safety tests in accordance with
the IEC EN 50106 Standard.
Summary of Contents for MILLENIUM JX