3.5.3
Configuration
Filtration setup has to be performed via LVLØ mobile application in Service section. Select Filtration.
Recommended runtime: Based on basic setup, LVLØ system will calculate minimal daily recommended
filtration pump runtime.
Automatic mode start hour: <select time> Select hour, when automatic filtration will start each day.
Automatic mode start minute: <select time> Select minute, when automatic filtration will start each day.
Filtration mode:
Automatic – Filtration is starting every day in time defined above with duration of minimal
recommended time.
Party (24h) – Filtration is running nonstop, until the mode is not changed, or stopped by user with
switch filtration pump.
Custom – Filtration pump is running based on custom timer.
Custom timer: Custom timer is used to define start and stop times according to needs. With
button, you
can add a new entry. There is a possibility to define as many entries per day as needed. For deleting an
entry, press button. To modify an entry, click entry and change as needed. If filtration mode is in Custom
mode and actual time is within defined entry, status will be changed to active, otherwise it is inactive.
Filtration pump: <OFF/ON> Manual control of filtration pump.
Winter mode runtime: <value> value in minutes. When LVLØ is running in winter mode, filtration pump is
started every hour for the preset duration in minutes to protect pool water from freezing.
Bottom drain flow: <OFF/ON> Manual control of circulation flow.
Flow switch: <not installed/optical/ultrasonic> Safety flow switch connection type. See chapter 3.6.
Filtration speed standard: <speed1/speed2/speed3/speed4> select desired speed profile, which will be used
for standard operation. Standard operation is when AUX are not active and pool cover is open.
Filtration speed AUX: <speed1/speed2/speed3/speed4> select desired speed profile, which will be used
when AUX or light output is active.
Filtration speed cover closed: <speed1/speed2/speed3/speed4> select desired speed profile, which will be
used when pool cover is closed.
Variable speed pump mode: <automatic/custom> in automatic mode LVLØ will use the speed profiles
defined for standard operation, AUX and cover closed. In custom mode, times have to be set for each speed
separately.
Speed 1 custom timer: <automatic/custom> set custom timers when filtration will be running with this
speed profile.
Speed 2 custom timer: <automatic/custom> set custom timers when filtration will be running with this
speed profile.
Speed 3 custom timer: <automatic/custom> set custom timers when filtration will be running with this
speed profile.
Speed 4 custom timer: <automatic/custom> set custom timers when filtration will be running with this
speed profile.