background image

 

 

Page

 

16

 

 

 

 

 

SECTION

 

7

 

 

  

MAINTENANCE

 

AND

 

ACCESSORIES

 

 

BATTERY

 

CHARGING

 

 

The

 

battery

 

will

 

indicate

 

a

 

need

 

to

 

be

 

charged

 

by

 

one

 

of

 

2

 

ways.

 

 
 

1.

  

The

 

meter

 

next

 

to

 

the

 

power

 

on/off

 

switch

 

on

 

the

 

front

 

panel

 

of

 

the

 

electronics

 

package

 

is

 

in

 

the

 

red

 

position.

  

Charging

 

is

 

recommended

 

when

 

the

 

unit

 

is

 

not

 

in

 

use

 

and

 

the

 

meter

 

is

 

half

 

way

 

up

 

in

 

the

 

green

 

area.

   

 
 

2.

   

The

 

LEDs

 

on

 

the

 

meter

 

do

 

not

 

illuminate

 

when

 

the

 

unit

 

is

 

turned

 

on

 

and

 

it

 

will

    

not

 

detect

 

a

 

target.

  

If

 

there

 

is

 

some

 

deflection

 

in

 

the

 

battery

 

level

 

meter

 

when

 

the

 

unit

 

is

 

turned

 

on,

 

but

 

it

 

does

 

not

 

operate,

 

this

 

indicates

 

that

 

the

 

battery

 

has

 

discharged

 

to

 

a

 

level

 

below

 

operational.

 

 

To

 

charge

 

the

 

battery,

 

connect

 

the

 

charger

 

to

 

the

 

CHARGE

 

jack

 

on

 

the

 

rear

 

panel

 

of

 

the

 

NJD

5's

 

electronics

 

package.

  

Plug

 

the

 

charger

 

into

 

an

 

AC

 

outlet.

  

The

 

charger

 

is

 

rated

 

for

 

110

240

 

VAC

 

primary

 

voltage.

  

A

 

full

 

charge

 

will

 

be

 

made

 

in

 

6

 

hours.

  

Charging

 

for

 

more

 

than

 

8

 

hours

 

can

 

overcharge

 

the

 

battery

 

and

 

shorten

 

its

 

useful

 

life.

 

 

The

 

BOOMERANG™

 

is

 

designed

 

to

 

use

 

its

 

battery

 

as

 

the

 

primary

 

power

 

source.

   

The

 

BOOMERANG™

 

may

 

be

 

used

 

while

 

charging.

   

Extended

 

operation

 

using

 

the

 

external

 

charger/power

 

supply

 

will

 

damage

 

or

 

shorten

 

the

 

life

 

of

 

the

 

battery.

   

 
 

FUSE

 

REPLACEMENT

 

 

If

 

the

 

LEDs

 

on

 

the

 

antenna

 

meter

 

box

 

do

 

not

 

light

 

and

 

the

 

meter

 

cable

 

is

 

properly

 

connected

 

and

 

the

 

power

 

switch

 

is

 

on

 

the

 

ON

 

position,

 

check

 

the

 

fuse.

  

The

 

fuse

 

holder

 

is

 

located

 

on

 

the

 

rear

 

panel

 

of

 

the

 

NJD

5

 

electronics

 

package

 

near

 

the

 

serial

 

number.

   

Spare

 

fuses

 

are

 

supplied

 

with

 

the

 

NJD

5.

  

Fuse

 

is

 

2.5

 

amps,

 

Type

 

GMA

 

(5x20mm).

 

 

  

REPLACEMENT

 

OF

 

ANTENNA

 

CLOTH

 

COVERING

 

 

 

1.

  

Remove

 

the

 

old

 

covering

 

which

 

is

 

held

 

on

 

with

 

Velcro

 

strips.

  

Do

 

not

 

remove

 

the

 

Velcro

 

from

 

the

 

antenna

 

or

 

tamper

 

with

 

the

 

antenna

 

cover

 

plate.

 

 

2.

   

Install

 

the

 

new

 

covering.

   

Use

 

only

 

an

 

ISA

 

replacement

 

covering.

   

Some

 

cloth

 

material

 

may

 

contain

 

metallic

 

threads

 

and

 

will

 

affect

 

the

 

operation

 

of

 

the

 

BOOMERANG™.

 

 

Summary of Contents for BOOMERANG NJD-5

Page 1: ...TS COPYRIGHT 2007 INFORMATION SECURITY ASSOCIATES Rev January 8 2008 Information Security Associates LLC BOOMERANG NON LINEAR JUNCTION DETECTOR MODEL NJD 5 OPERATOR S MANUAL ISA Information Security A...

Page 2: ...tup 6 Section 4 Operation 9 Important Notes On Full Scale Readings 10 Use of Attenuator 11 Section 5 Operational Notes and Hints 12 Phantom Returns and Interfering Signals 12 Resolving Indications of...

Page 3: ...ped in avalanches and more commonly are seen in electronic article surveillance systems to deter shoplifting Detectors of this sort consist of a transmitter and a receiver that is tuned for instance t...

Page 4: ...r metallic oxides These metallic oxides commonly occur in building and furniture construction and are found in furniture and other office type products like three ring binders and paper clips In this...

Page 5: ...0 or 2745 MHz The switch marked Normal 2nd Only is used to turn off the 3rd harmonic receiver This is useful when a return needs to be evaluated in depth The audio section of the NJD 5 switches betwee...

Page 6: ...ead of the bracket on the antenna has two slots machined into it to be used to lock the antenna in certain orientations CABLES The NJD 5 electronics package contains a transmitter and receiver These a...

Page 7: ...strap is not recommended because it leads to rapid operator fatigue and discomfort The backpack harness allows the NJD 5 to be carried on the lower back where controls are accessible and weight is ev...

Page 8: ...be loosened 4 Connect a set of coaxial cables to the antenna The coaxial cable assembly is built with male and female connectors to prevent incorrect connection of antenna elements 5 Connect the mete...

Page 9: ...come on Turn the knob slightly back clockwise until the tone stops Set the Attenuator to the 9 dB setting 12 Remove the test target from its envelope Hold it between thumb and forefinger in front of t...

Page 10: ...he short side of the antenna Try different orientations of the antenna and the target to get the strongest return signal 17 Attach the backpack style carrying strap Clip the short ends of the strap to...

Page 11: ...le before the 3rd harmonic meter displays any return at all 4 If the non linear junction you have detected is a metal to metal contact such as a sheetrock screw in a steel stud or two dissimilar metal...

Page 12: ...This indicates a corroded junction because of the high level of 3rd harmonic IMPORTANT NOTE ON FULL SCALE READINGS If both 2nd and 3rd harmonic displays are full scale when looking at a target the ope...

Page 13: ...ble electronic devices They may be detected in many directions from some distance away When this is the case it may be difficult to determine what exactly the NJD 5 is detecting The solution to this d...

Page 14: ...ng detected by the NJD 5 which appears to come from all directions and changing the direction the antenna is pointing in does not eliminate the signal This is caused by a signal from another transmitt...

Page 15: ...ng room If it is suspected that a legitimate electronic device is the cause of the return move the device and use the NJD 5 to look from the adjoining area back into the room under investigation at th...

Page 16: ...fices this molding is a rubber or plastic strip that can be removed and re installed If the wall has a papered surface make a slit in the paper and peel it back enough to create a small opening into t...

Page 17: ...when the battery reaches a certain level of charge This avoids the gradual deterioration of detection ability that occurs when the battery reaches a critical level of discharge 4 Take care when connec...

Page 18: ...full charge will be made in 6 hours Charging for more than 8 hours can overcharge the battery and shorten its useful life The BOOMERANG is designed to use its battery as the primary power source The...

Page 19: ...nt 1 41079 Target 4 41069 Velcro Strips 1 41055 Manual 1 41075 Small Accessories Pouch 1 41080 Mono Headset w 1 4 Plug 1 41085 Poke Stick 1 41166 3 foot AC Cord 1 41164 Switching DC Power Supply Charg...

Page 20: ...examination by Information Security Associates LLC shall be found to have been originally defective INFORMATION SECURITY ASSOCIATES LLC SHALL NOT BE LIABLE FOR LOSS OR DAMAGE CAUSED EITHER DIRECTL Y O...

Reviews: