© IS Technologies Co., Ltd. PAGE
23
/
41
2.2 LED Functions
There are 4 LED
’
s, located above the display their functions are as follows:
LED
Condition
Function
Detect &
Level
Flashing
together
Indicates Normal Operation
Mode selected = Level
Detect &
Distance
Flashing
together
Indicates Normal Operation
Mode selected = Distance
Detect &
Space
Flashing
together
Indicates Normal Operation
Mode selected = Space
Detect
Flashing alone
Indicates that ULM-1000C is
detecting an echo but checking if
the value is correct.
The reasons
None
All Off Display
indicates
flashing “E*”
Indicates that ULM-1000C has gone
into Fail condition.
E0 means there is no reflected echo
received.
E1 means transducer and
2.3 Measuring Mode
This mode is used once the ULM-1000C has been set up in program mode. It is
also the default mode that the unit reverts to when it resumes operation a
ft
er
a power failure.
When the ULM-1000C is switched on for the
fi
rst time, it will display, in
centimeters, the distance from the transducer face to the target.
A
ft
er programming is complete, any switched outputs that are set will
operate when the level reaches the relevant setpoint. Whilst in Run Mode the
Detect and Distance LED
’
s provide information on the status of the signal.
Summary of Contents for ULM-1000C
Page 1: ...IS Technologies Co Ltd PAGE 1 41 Please read this manual attentively before installation...
Page 5: ...IS Technologies Co Ltd PAGE 5 41 Safety Guide Instruction...
Page 8: ...IS Technologies Co Ltd PAGE 8 41 Product Description ULM 1000C...
Page 13: ...IS Technologies Co Ltd PAGE 13 41 INSTALLATION...
Page 18: ...IS Technologies Co Ltd PAGE 18 41 Wiring...
Page 20: ...IS Technologies Co Ltd PAGE 20 41 Operation...
Page 26: ...IS Technologies Co Ltd PAGE 26 41 Programing...
Page 36: ...IS Technologies Co Ltd PAGE 36 41 Maintenance...
Page 38: ...IS Technologies Co Ltd PAGE 38 41 Trouble shooting...