11
Chapter 4 Menu Guide
Application Menu Option
1) Password
Password is needed to enter the operation mode.
After setting the password using UP/DOWN button, press MODE to get into the operation mode.
- Password : 412
2) Measure Type
Factory Set = Level
This option sets the mode of operation when in run mode, and can be set to one of the following:
Option
Description
Level
Display shows how full the vessel is with respect to the
Empty
(0% of
Span)
Distance
Display shows the distance from the transducer face to the surface.
Space
Display shows how an empty vessel is with respect to
Full
(100% of
Span) i.e. how much space is available in the vessel.
3) Bottom Distance
FactorySet=8.50/12.50m
This option sets the maximum distance from the face of the transducer to the empty point
BOTTOM DISTANCE SET
BOT : 12.50m
PASSWORD IDENTITY
PASSWORD :
MEASURE TYPE SET
LEVEL