4510-HDA.ib.Rev0.doc
Page 5 of 12
19/07/2006
Configuration
Link Settings:
LK2 IN
Reclocker set for HD or SD operation (Default position IN).
OUT
Reclocker automatically bypassed on lock loss.
LK3 IN
Selects Manual PLL rate.
OUT
Selects Auto PLL rate (Default position OUT, LK3 not installed).
LK4, LK5, LK6 Set manual PLL rate.
Must be left open when Auto PLL selection (LK3 OUT) used.
Rate
(Mb/s) LK4
LK5
LK6
143
0 0 0
270
0 1 0
360
1 1 0
540
0 0 1
1485
1 0 1
LK7 N.C.
Output alarm switches to ground on loss of input, or loss of power.
N.O.
Output alarm switches (breaks) from ground on loss of input, or
loss of power.
Location of links & user settings
The following location diagram is not to scale and is intended only to assist in finding the location of links and other
settings, which may need to be changed by the user during
Configuration
.
Plug-in
SNMP
LK
2
LK7
N.C.
N.O.
LK
3
LK4 LK5 LK6
GND
COM.
+3V