SNMP with IRT Products: 

 
IRT Electronics currently employs SNMPv1 with its 4000 series frame. The frame acts as an 

agent

 when fitted with 

a CDM-4000 module. This module has its own designated slot next to the power supply so as to not affect the 
number of modules that the frame will take. Communication between the 

NMS

, the frame and its loaded modules are 

via this CDM-4000 module. Note that the 

NMS

 software is third party and not supplied by IRT Electronics. 

 
Ethernet connection for SNMP operation is via an RJ45 connector on the rear of the frame, below the mains inlet. 
Ethernet rate runs at either 10 baseT or 100 baseT. 
 
Frame parameters, such as Name, Address and Location, are set via an RS232 interface, a D9 connector on the rear 
of the frame below the mains inlet. A software terminal emulator, such as Tera Term or HyperTerminal, is used for 
setting and reading the parameters of the frame. 
 
IRT modules that are SNMP compatible need a plug-in SMU-4000 module with a program relevant to the module 
that it is plugged into. Depending on the module, besides the module identification, parameters such as alarm states, 
inputs and controls etc. are communicated to the CDM-4000 

agent

 via a data bus on the rear of the frame. Thus the 

CDM-4000 collects information on what is loaded within the frame, what positions they occupy, and their current 
status for communication to the 

NMS

 when the 

NMS

 sends a request for information.  

 
In the event of a major alarm from any of the SNMP compatible modules, or power supplies, a 

trap

 is automatically 

sent by the CDM-4000 

agent

 to the 

NMS

 without any prompting by the 

NMS

. This alerts the operator to any fault 

conditions that may exist that need immediate attention. 
 
 
 
 

FRU-4000

FRAME

110/240 V  50/60 Hz

0.7 A (max.)

FUSES

110/120 Vac

1A  S.B.

220/240 Vac

500 mA  S.B.

      AS3260 approval no.: CS6346N
Ass. no.: 804692     

+

-

48Vdc

Alarm

RS232 

Ethernet

IRT SNMP Connections 

IRT modules fitted 

with SMU-4000 

PSU’s

CDM-4000

IRT 4000 Series 

IRT 4000 Series 

IRT modules fitted 

with SMU-4000 

PSU’s

CDM-4000

Network 

Ethernet Cable 

Ethernet Cable 

Ethernet Cable 

NMS 

IRT 4000 Series SNMP Setup

Summary of Contents for HDA-4510

Page 1: ...and manufactured in Australia IRT can be found on the Internet at http www irtelectronics com I R T Electronics Pty Ltd A B N 35 000 832 575 26 Hotham Parade ARTARMON N S W 2064 AUSTRALIA National Pho...

Page 2: ...11 Drawing List Index 12 This instruction book applies to units later than S N 0506001 Operational Safety WARNING Operation of electronic equipment involves the use of voltages and currents that may...

Page 3: ...al and automatically adjust the output driver slew rate to suit Front panel LEDs indicate when an input signal is present and also whether it is either an HD or SD type of signal A relay alarm output...

Page 4: ...signal present HD LED green when input signal is 1 485 Gb s HD SD LED yellow when output signal is 270 360 or 540 Mb s SD Power requirement Voltage 28 Vac CT 14 0 14 or 16 Vdc Consumption 4 0 VA Gene...

Page 5: ...Auto PLL selection LK3 OUT used Rate Mb s LK4 LK5 LK6 143 0 0 0 270 0 1 0 360 1 1 0 540 0 0 1 1485 1 0 1 LK7 N C Output alarm switches to ground on loss of input or loss of power N O Output alarm swit...

Page 6: ...and chassis earth No attempt should be made to break this connection Installation in frame or chassis See details in separate manual for selected frame type Digital Input and Outputs Input and output...

Page 7: ...the module that it is being plugged into it then needs to be programmed via the pins on the topside of the SMU 4000 Note that installation will generally be done by IRT Electronics at the time of ord...

Page 8: ...t rear panel connector diagrams The following front panel and rear assembly drawings are not to scale and are intended to show connection order and approximate layout only SK1 2 1 SK10 2 Alarm SK10 1...

Page 9: ...that information into a form compatible with SNMP The agent therefore acts as an interface between the NMS and the managed devices The NMS sends a request message and control commands for the managed...

Page 10: ...tible need a plug in SMU 4000 module with a program relevant to the module that it is plugged into Depending on the module besides the module identification parameters such as alarm states inputs and...

Page 11: ...extended by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment...

Page 12: ...4510 HDA ib Rev0 doc Page 12 of 12 19 07 2006 Drawing List Index Drawing Sheet Description 804999 1 HDA 4510 HD SD Distribution Amplifier Schematic Diagram...

Page 13: ...RE OR BREAK TO GROUND ON ALARM AS SET BY LK7 3 2 1 Q2 BSS123 1 2 C36 4 7uF 3 8 RL1A V23026 10 1 5 RL1B 1 3 2 D2 BAS16 1 2 C37 47nF ALARM RX TX SIGNAL SEL2 SEL1 SEL0 HD SD MAN Control Interface 804999i...

Reviews: