SNMP with IRT Products: 

 
IRT Electronics currently employs SNMPv1 with its 4000 series frame. The frame acts as an 

agent

 when fitted with 

a CDM-4000 module. This module has its own designated slot next to the power supply so as to not affect the 
number of modules that the frame will take. Communication between the 

NMS

, the frame and its loaded modules are 

via this CDM-4000 module. Note that the 

NMS

 software is third party and not supplied by IRT Electronics. 

 
Ethernet connection for SNMP operation is via an RJ45 connector on the rear of the frame, below the mains inlet. 
Ethernet rate runs at either 10 baseT or 100 baseT. 
 
Frame parameters, such as Name, Address and Location, are set via an RS232 interface, a D9 connector on the rear 
of the frame below the mains inlet. A software terminal emulator, such as Tera Term or HyperTerminal, is used for 
setting and reading the parameters of the frame. 
 
IRT modules that are SNMP compatible need a plug-in SMU-4000 module with a program relevant to the module 
that it is plugged into. Depending on the module, besides the module identification, parameters such as alarm states, 
inputs and controls etc. are communicated to the CDM-4000 

agent

 via a data bus on the rear of the frame. Thus the 

CDM-4000 collects information on what is loaded within the frame, what positions they occupy, and their current 
status for communication to the 

NMS

 when the 

NMS

 sends a request for information.  

 
In the event of a major alarm from any of the SNMP compatible modules, or power supplies, a 

trap

 is automatically 

sent by the CDM-4000 

agent

 to the 

NMS

 without any prompting by the 

NMS

. This alerts the operator to any fault 

conditions that may exist that need immediate attention. 
 
 

FRU-4000

FRAME

110/240 V  50/60 Hz

0.7 A (max.)

FUSES

110/120 Vac

1A  S.B.

220/240 Vac

500 mA  S.B.

      AS3260 approval no.: CS6346N
Ass. no.: 804692     

+

-

48Vdc

Alarm

RS232 

Ethernet

IRT SNMP Connections 

IRT modules fitted 

with SMU-4000 

PSU’s

CDM-4000

IRT 4000 Series 

IRT 4000 Series 

IRT modules fitted 

with SMU-4000 

PSU’s

CDM-4000

Network 

Ethernet Cable 

Ethernet Cable 

Ethernet Cable 

NMS 

IRT 4000 Series SNMP Setup

Summary of Contents for Eurocard MEM-4550

Page 1: ...nufactured in Australia IRT can be found on the Internet at http www irtelectronics com I R T Electronics Pty Ltd A B N 35 000 832 575 26 Hotham Parade ARTARMON N S W 2064 AUSTRALIA National Phone 02...

Page 2: ...vice 13 Equipment return 13 This instruction book applies to units later than S N 0411001 Operational Safety WARNING Operation of electronic equipment involves the use of voltages and currents that ma...

Page 3: ...and half full duplex data modes The ASI port is switch selectable to operate at a payload data rate of either 10 8 Mb s or 108 Mb s The Ethernet port has automatic MDI MDI X detection This detects whe...

Page 4: ...ex Half Duplex ASI SW 1 4 Program Number 4550 Program Number 4551 SW 1 5 ASI Payload Rate 108 Mb s 10 8Mb s SW 1 8 Enable SNMP if fitted Front Panel Indicators Ethernet LINK Ethernet link connected Gr...

Page 5: ...N 100 Base T SW1 3 OFF Half Duplex Operation ON Full Duplex Operation Note SW1 2 and SW1 3 switch settings only work with SW1 1 set to off position ASI Parameters SW1 4 OFF ASI Program Number set to 4...

Page 6: ...is made between signal earth and chassis earth No attempt should be made to break this connection Installation in frame or chassis See details in separate manual for selected frame type Ethernet Conn...

Page 7: ...up with the three sets of multipin sockets on the main PCB module Align all pins and then gently press the SMU 4000 all the way down into place If the SMU 4000 is not already programmed with the corr...

Page 8: ...OR 4 GND ASI OUTPUT 1 2 3 4 Front rear panel connector diagrams The following front panel and rear assembly drawings are not to scale and are intended to show connection order and approximate layout o...

Page 9: ...s Green FDX Full Duplex Mode Green ACT LAN Activity Green ASI LINK Ethernet link connected Green 10 100 Rate 10 8 Mb s Orange 108 Mb s Green ERR Error in ASI input Red 188 Input ASI 188 byte Green Ea...

Page 10: ...that information into a form compatible with SNMP The agent therefore acts as an interface between the NMS and the managed devices The NMS sends a request message and control commands for the managed...

Page 11: ...tible need a plug in SMU 4000 module with a program relevant to the module that it is plugged into Depending on the module besides the module identification parameters such as alarm states inputs and...

Page 12: ...ng received on the ASI input An indication that a link has been established on the Ethernet port An indication of which of the two available speeds that the Ethernet port is operating 10 or 100 An ind...

Page 13: ...extended by IRT only to the extent obtainable from the component supplier Equipment return Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment...

Reviews: