Wiring Details

CONNECTING TO WATERMARK SENSORS

Use waterproof wire connectors.

1.Insert one side of a Node wire pair and one side of the corresponding sensor wire pair into
one connector. Repeat for the other wire in the Node pair and the remaining sensor wire with
another connector. One connector per individual Node wire is needed.

Be sure to 

INDIVIDUALLY insulate ALL unused wires. DO NOT leave unused Node wires 

un-insulated and allowed to corrode, touch each other or touch the metal pole.

2.Repeat for each sensor being installed.

NOTE: Wires are paired by color. One is a solid color and the other is the 
same color with a black stripe.

*

*

After registration on SensMitWeb, notice that the sensor data in the graph view is color coded to the wire

colors on the Nodes. WATERMARK lines are green, blue and gray (for white), the temperature line is red, the
rain event is indicated by yellow vertical bars and irrigation events are brown vertical bars.

9

Summary of Contents for IRROmesh

Page 1: ...locations to verify that distances are acceptable and potential obstructions are avoided will make the physical deployment of the hardware much easier Avoid installation near areas with potentially s...

Page 2: ...ovide in fill near relaying Nodes see Figure 4 D There is a limitation to the number of Nodes that can be in a path and how many total paths can feed to the Base If all the data from several Nodes has...

Page 3: ...tions for your device on pages 4 to 5 Installation BASE At the pre determined Base location uncover the solar panels and slide the switch inside the Base enclosure to the ON position Mount on any stur...

Page 4: ...d and retrieved manually with a laptop computer A free download of 975L WaterGraph Software is provided to retrieve view and graph data NOTE The Logger is used to batch download data but cannot be use...

Page 5: ...rk to upload to SensMitWeb Once you have completed registration you will be able to view your Nodes and confirm that the network is operating properly You will also be able to access a host of diagnos...

Page 6: ...One connector per individual Node wire is needed Be sure to INDIVIDUALLY insulate ALL unused wires DO NOT leave unused Node wires un insulated and allowed to corrode touch each other or touch the met...

Page 7: ...11 pipe with a transition solvent PVC to ABS cement The pipe becomes a conduit to protect the sensor wires Also this makes the sensor easier to push into the access hole and remove if desired The top...

Page 8: ...mitting data to the Web To rectify add SensMitPath to the list of approved programs on your anti virus exceptions page then click OK or Allow to permit access RESETTING PROCEDURES On occasion it may b...

Page 9: ...nused wires DO NOT leave unused Node wires un insulated and allowed to corrode touch each other or touch the metal pole 2 Repeat for each sensor being installed NOTE Wires are paired by color One is a...

Page 10: ...___________ Node Descriptive Name ____________________________________________________________________ Node ID _______ _______ _______ _______ _______ _______ _______ _______ Type Relay EndX Node Loca...

Page 11: ...Notes or System Layout Diagram 11...

Page 12: ...television reception which can be determined by turning the equipment OFF and ON the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocat...

Reviews: