IRROMETER IRROmesh Installation And Operating Instructions Manual Download Page 5

associated to the fully charged Base outside. Take the
PC Link to within 2' of the Base and wait for the green
light on the PC Link to flash – indicating association
when the system is awake. This will typically take
about 15 minutes.

Installation of the PC Link: First download
SensMitPath software to your Windows

®

OS

computer from

http://www.IRROMETER.com/download/

sensmit_installer.exe

The entire SensMitPath software package is 

available through this link or on the IRROMETER
Products webpage under Data Loggers / 975 Wireless 
Mesh System / SensMitPath Installer. Downloading
SensMitPath from the IRROMETER web site ensures
you get the program designed for the IRROmesh
firmware version you purchased. Install the program
with administrative privileges. You may need to allow
SensMitPath access through your anti-virus software
in order to access the Internet. Once the program icon
appears on your desktop, double-click to open the
software. Make sure the numerical universal time
indicated at the bottom left of the dialogue box is visible
and updating. If not, with some versions of Windows

®

,

you will need to restart your computer after installing
SensMitPath. Make sure the software is always
running and, if you are streaming real-time, that the
computer you are using has all its ‘sleep’ and ‘rest’
functions disabled. If your computer turns off/sleeps,
the data flow will stop. Placing SensMitPath on your
Start Menu will enable the application to restart
automatically in the event of a computer reboot.

Plug the PC Link into the host computer by its

supplied USB cable. The Base signal will travel to it
through non-metallic walls and windows, but range is
less than with outdoor device options. The host
computer must remain turned on and online in order to
continuously stream data. Data can be viewed on any
WEB enabled computer, smartphone or tablet device.
(see Figure 8)

Data Collection with a PC Link: First activate your
system at 

www.SensMitWeb.com and become a

subscriber (see ‘Subscription Registration’ on page 6).
Additional information regarding the software is
available on the SensMitWeb.com ‘Resources’ page.
When running, this utility detects your USB connection
and automatically connects to the PC Link. This
enables any data from your network to upload to
SensMitWeb. Once you have completed registration,
you will be able to view your Nodes and confirm that
the network is operating properly. You will also be able
to access a host of diagnostic features.

Off-Season Shut-Down of the PC Link: Unplug the
PC Link from the computer and turn off the
SensMitPath software.

CELLULAR GATEWAY — 975G-BP

Data is automatically transferred to the WEB by the

Cellular Gateway, where it is viewed and stored.
(Subscription required)
NOTE: Cellular data coverage must be available at the 
gateway location.

Charging and Associating the Cellular Gateway:
The Cellular Gateway is powered by its supplied solar
rechargeable battery pack and will be operational
when both battery terminals are connected. (Units are
shipped with one battery terminal disconnected for
safety.) 
To associate, include the Cellular Gateway
when charging and associating the Base and Nodes as
described on page 2.
Installation of the Cellular Gateway: The Cellular 
Gateway and accompanying Solar Recharging Battery
Pack can be installed in the field at the Base location,
usually on the same mounting pole or up to 400' (122
m) from the Base. A minimum clearance distance of 3
ft (1m) should be maintained between the Base and
the Cellular Gateway. Mount the Cellular Gateway, like
the Base, on any sturdy post or pole using supplied
mounting brackets, as described on page 3. 

If using the same pole as the Base, mount the Base

at the top of the pole, then the Solar Panel, the Cellular
Gateway and finally the Battery Pack, in that order. For
wiring details see the ‘IRROmesh Mounting Base &
Cell Gateway’ video at: 

http://IRROMETER.com/videos.html 

Record the 20 digit SIM card identification number

from the SIM card for 975G or the MEID for 975G-V
from the label on the modem here:

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

It will be required to register an account on
SensMitWeb. 
Data Collection with the Cellular Gateway: To use the
Cellular Gateway you will first need to activate your system
at www.SensMitWeb.com to become a subscriber (see
‘Subscription Registration’ on page 6). 
Cellular data
charges are included in the subscription rates. During
Cellular Gateway registration you will be prompted to enter
the 20 digit modem SIM card ID or MEID number in the
Registration tab. Once you have completed registration,
you will be able to view your Nodes and confirm that the
network is operating properly. You will also be able to
access a host of diagnostic features.

5

Summary of Contents for IRROmesh

Page 1: ...locations to verify that distances are acceptable and potential obstructions are avoided will make the physical deployment of the hardware much easier Avoid installation near areas with potentially s...

Page 2: ...ovide in fill near relaying Nodes see Figure 4 D There is a limitation to the number of Nodes that can be in a path and how many total paths can feed to the Base If all the data from several Nodes has...

Page 3: ...tions for your device on pages 4 to 5 Installation BASE At the pre determined Base location uncover the solar panels and slide the switch inside the Base enclosure to the ON position Mount on any stur...

Page 4: ...d and retrieved manually with a laptop computer A free download of 975L WaterGraph Software is provided to retrieve view and graph data NOTE The Logger is used to batch download data but cannot be use...

Page 5: ...rk to upload to SensMitWeb Once you have completed registration you will be able to view your Nodes and confirm that the network is operating properly You will also be able to access a host of diagnos...

Page 6: ...One connector per individual Node wire is needed Be sure to INDIVIDUALLY insulate ALL unused wires DO NOT leave unused Node wires un insulated and allowed to corrode touch each other or touch the met...

Page 7: ...11 pipe with a transition solvent PVC to ABS cement The pipe becomes a conduit to protect the sensor wires Also this makes the sensor easier to push into the access hole and remove if desired The top...

Page 8: ...mitting data to the Web To rectify add SensMitPath to the list of approved programs on your anti virus exceptions page then click OK or Allow to permit access RESETTING PROCEDURES On occasion it may b...

Page 9: ...nused wires DO NOT leave unused Node wires un insulated and allowed to corrode touch each other or touch the metal pole 2 Repeat for each sensor being installed NOTE Wires are paired by color One is a...

Page 10: ...___________ Node Descriptive Name ____________________________________________________________________ Node ID _______ _______ _______ _______ _______ _______ _______ _______ Type Relay EndX Node Loca...

Page 11: ...Notes or System Layout Diagram 11...

Page 12: ...television reception which can be determined by turning the equipment OFF and ON the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocat...

Reviews: