12
Control Feature Setup Options
Setup Menu Options
13
Setup Menu Options
The following
Setup
features are accessed through the
ET Setup
menu (
MENU
_
SETUP
_
ENTER
).
All setup parameters are selected, adjusted and entered using the
NEXT/BACK
,
/
and
SAVE
keys.
Auto Program Adjust:
In all cases, Climate Logic regulates the
run time of all stations assigned to Program A. The Auto Program
Adjust feature enables stations assigned to Program B, or Programs
B and C to be regulated as well.
Watering Restriction Setup:
This feature enables the Climate
Logic system to restrict watering for a specified daily time period.
The restriction-period start time can be set to any hour of the day.
The duration period can be set from 0 to 24 hours, in 30-minute
increments.
Schedule Update Time:
The Weather Sensor transmits weather-
related data to the Receiver Module at regular intervals throughout
the day. At the default time of 8:00 p.m., the watering adjustment
factor for the next 24 hours is calculated and updated on the
Home
screen. The Schedule Update Time can
be set to any hour of the day, but is recommended to occur between scheduled watering operations.
Average Percent Days:
This setting defines how many days of compiled weather data are used to calculate
the current watering adjustment % factor. By default, Climate Logic compiles data from the three previous
days to provide a moderately smooth adjustment factor. This feature can be adjusted from 1 to 7 days.
Decreasing the number of days, increases the adjustment variation; increasing the number of days results
in less variation and a smoother daily average.
Climate Logic System Operation Control Feature Setup Options
The Climate Logic system control features, accessible through the
Setup
and
Utility
menu screens,
determine how and when the system displays information and performs various functions that regulate
weather-defined automatic irrigation. The control feature-set, listed below in menu order, includes the
factory default setting and the setup parameter for each.
Setup Menu Features
Default
Setup Parameter
Auto Program Adjust
Program A Program A, A
&
B or A, B
&
C
Water Restriction Start Time None
Any hour
Water Restriction Duration
None
0–24 hours (in ½-hour increments)
Schedule Update Time
8:00 p.m.
Any hour
Average Percent Days
3
1–7 Days
Freeze Temperature
39° F (4° C) 35°–45° F (2°–7° C) (in 2° increments)
Dry-out days
0.5
0–3 days (in ½-day increments)
Utility Menu Features
Default
Setup Parmater
Contrast
Balanced
Increase/Decrese (incremental)
Units (of measure/time format) English, 12H Metric,
24H
Note:
History, Default, Loader, and About utility menu items are provided for reference and service use only, and
do not provide user-defined setup options. Refer to page 17 for detailed History feature information.