background image

INSTALLATION AND OPERATION MANUAL

     

WARNING

 

Hot! Do not touch!  The glass and surfaces of this appliance will 

be hot during operation and will retain heat for a while after 

shutting off the appliance.   Severe burns may result. 

• 

 

Carefully supervise children in the same room as appliance.

Save These Instructions 

For Future Reference

A French manual is available upon request. Order P/N 900102-00.

Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de 

la pièce 900102-00.

This appliance must be properly installed and operated in order to prevent the 

possibility of a house fire. Please read this entire installation and operation 

manual before installing and using your wood fireplace insert. Failure 

to follow these instructions could result in property damage, bodily 

injury or even death. Contact your local building or fire officials 

to obtain a permit and information on any installation re-

quirements and inspection requirements in your area.

EPA Certified

Wood-Burning 

Fireplace Inserts

P/N 900101-00, Rev. A, 04/2015

P900101-00

Wood Fireplace Inserts

Performer™ Models C210 and CA210

Performer™ CA210

Performer™ C210

Report #  14-185

C

US

Summary of Contents for Performer C210

Page 1: ...ro de la pi ce 900102 00 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and operation manual before ins...

Page 2: ...Chimney Requirements 10 Installation Procedures Masonry Chimney 10 Positive Flue Connection 11 Installation Procedure Factory Built Zero Clearance Fireplaces 11 Fireplace Pre Installation Preparation...

Page 3: ...by a professionalchimneysweep Donotattempttoburnoutheavy creosoteaccumulationswithahotfire Iflargeaccumulations are occurring review your burning procedures 14 If a creosote fire should develop the fi...

Page 4: ...ccessories may turn color stove glass may develop a haze which will not come off with cleaning Overfiring of a stove or fireplace insert is a condition where excessive temperatures are reached beyond...

Page 5: ...tion is essential when using a Solid Fuel Burning heater In well insulated and weather tight homes it may be difficult to establish a good draft up the chimney caused by a shortage of air in the home...

Page 6: ...f three burns The first two should last for 20 minutes each at 250 degrees the appliance should be allowed to cool completely between each burn The third should be a burn of at least 450 degrees F for...

Page 7: ...nstall the two remaining boards where you originally installed the first two boards on each side of the baffle support and pushed against the rear of the unit The stainless steel support hanger should...

Page 8: ...from the door opening of the unit Canada 18 450 mm minimum hearth extension on all stoves and inserts as measured from the door opening of the unit Minimum distance of floor protection to the side 8...

Page 9: ...asterisk indicates it is a value taken from Tables 2 and 3 FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS Using the k formula Minimum k value per Inch of Specified min thickness of alternate ma...

Page 10: ...nter of the fireplace opening and push it back until the surround brackets are approximately 2 51 mm away from the fireplace front 7 Install the side surround panels and push the insert up snug agains...

Page 11: ...pproved methods of achieving a positive flue connection See Figure 9 A qualified installer should evaluate the existing fireplace to determine the best method for achieving a positive flue connection...

Page 12: ...Factory Built Zero Clearance Fireplaces Fireplace Pre Installation Preparation NOTE IHP RECOMMENDS PROFESSIONAL INSTALLATION BY A LICENSED AND BONDED INSTALLER SEE YOUR DEALER FOR RECOMMENDATIONS IMP...

Page 13: ...Part H5296 is available to fill the space between the insert and the hearth protection Install the brick and baffle as per Page 7 Chimney Liner Installation Installing the Insert Post Installation Ch...

Page 14: ...ermometer can be a helpful tool to help ensure you are not over firing your appliance and it will also ensure you are burning fuel at a rate that is most efficient Place a stove thermometer on the top...

Page 15: ...turn off continue to rotate the knob counterclockwise until it clicks OFF Blower Speed Control Knob rheostat Manual Auto Rocker Switch Blower Operation Guidelines While in auto operation mode the blo...

Page 16: ...locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the fireplace insert with the draft open for a few m...

Page 17: ...are included with the graphite CAUTION Cleaning Glass Ensure appliance is cold prior to cleaning glass A commercial glass cleaner designed for stoves is recommended Do not use abrasivecleaners Donotc...

Page 18: ...rotective gloves are recommended Step 5 Install New Glass Assembly Install the new glass with gasket in recess on door back use only factory supplied 5mm ceramic glass Do not substitute Step 6 Reinsta...

Page 19: ...ss above SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blankets are pushed back flush with the front of the...

Page 20: ...requirements in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and or nausea If you...

Page 21: ...dware 18 H8082 Replacement Power Cord 19 H8074 UHPII Blower Cage Snap Switch Black H8075 UHPII Blower Cage Snap Switch Gold H8076 UHPII Blower Cage Snap Switch Nickel H8077 UHPII Blower Cage Snap Swit...

Page 22: ...22 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 33 34 36 36 45 46 47 37 37 35 40 44 40 38 38 38 41 38 38 38 41 38 38 42 38 38 38 38 42 38 38 39 39 43 39 39 Replacement Parts Model C210 and CA210...

Page 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 16 29 17 15 32 18 19 Replacement Parts Model C210 and CA210 Door Parts Blower Parts...

Page 24: ...N 71021 WFT2640 B Black 26 3 4 x 40 71022 WFT2648 B Black 26 3 4 x 48 71025 WFT3040 B Black 30 3 4 x 40 71026 WFT3048 B Black 30 3 4 x 48 71007 WFT2640 G Gold 26 3 4 x 40 71008 WFT2648 G Gold 26 3 4 x...

Page 25: ...a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning d...

Page 26: ...a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices a...

Reviews: