background image

19

REPLACEMENT PARTS - MODEL C260

Summary of Contents for Legacy C260

Page 1: ...um ro de la pi ce 900104 00 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and operation manual before...

Page 2: ...equired Clearances 7 Hearth Protection 8 USING THIS MANUAL Please read and carefully follow all of the instructions found in thismanual Pleasepayspecialattentiontothesafetyinstructions provided in thi...

Page 3: ...by a professionalchimneysweep Donotattempttoburnoutheavy creosoteaccumulationswithahotfire Iflargeaccumulations are occurring review your burning procedures 14 If a creosote fire should develop the fi...

Page 4: ...1990 This heater has been developed tested and constructed in accordance with the requirements of UL 1482 ULC S628 and HUD standards and is listed by OMNI Test Laboratories Portland OR It has been ap...

Page 5: ...ire The chimney and chimney connector should be inspected at least once monthly during the heating season to determine if a creosote buildup has occurred If creosote has accumulated 1 8 3mm or more it...

Page 6: ...ation will be installing the front baffle boards The front baffle boards will be the two remaining baffle boards which are the larger two baffle boards of the four baffle board kit They will be instal...

Page 7: ...to the side 8 200 mm This is measured from the sides of the door opening in the USA and from the sides of the insert in Canada This appliance may be installed in a bedroom in the United States Model A...

Page 8: ...icates it is a value taken from Table 2 Using the k formula Minimum k value per Inch of Specified min thickness of alternate material kM x thickness alternate k value per inch of listed material TM of...

Page 9: ...dge of both the top and side surround panels 9 Install the surround panels loosely align and tighten Check for a tight fit against the fireplace 10 Locate the draft rod extension 5 16 8 mm round by 11...

Page 10: ...positive flue connection in masonry fireplaces is to secure a seal off plate i e 22 gage sheet steel in the fireplace throat using masonry screws Other acceptable methods include packing noncombustib...

Page 11: ...MMENDS PROFESSIONAL INSTALLATION BY A LICENSED AND BONDED INSTALLER SEE YOUR DEALER FOR RECOMMENDATIONS IMPROPER INSTALLATION OR MIS USE WILL VOID YOUR WARRANTY AND CREATE A SERIOUS SAFETY HAZARD Remo...

Page 12: ...e the front door is slightly open Once kindling is burning well larger pieces of wood may be added then the door should be fully closed if there was the need to keep it slightly open during start up D...

Page 13: ...ting When the stove or insert cools down the blower will automatically turn off Rheostat Operation The highest blower speed is obtained by turning the rheostat knob clockwise until it clicks ON then r...

Page 14: ...riment with different loading configurations to achieve longer burns Try loading the wood from side to side and nesting it in the ashes to prevent airflow under and around the wood Fresh wood should b...

Page 15: ...h remove the 6 retainer screws from the faceplate To locate screws peel back the door gasket as necessary Step 3 Disassemble Door Assembly Flip door assembly over to be face up Separate faceplate from...

Page 16: ...e and Clean Glass above SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blanket is pushed back flush with the...

Page 17: ...assembly DO NOT Close the door tightly during Burn In period DO Be sure to clean any fingerprints from optional accessories that have plated surfaces before burning the appliance Clean the plated surf...

Page 18: ...er Cage Snap Switch Black H8070 UHPI Blower Cage Snap Switch Gold H8076 UHPI Blower Cage Snap Switch Nickel H8077 UHPI Blower Cage Snap Switch Brushed Gold H8078 UHPI Blower Cage Snap Switch Brushed N...

Page 19: ...19 Replacement Parts Model C260...

Page 20: ...20 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 7 11 10 6 9 5 4 4 1 8 2 3 Replacement Parts Model C260 16 29 17 15 32 18 19 Door Parts Blower Parts...

Page 21: ...71013 WFT3340 G Gold 33 x 40 71014 WFT3348 G Gold 33 x 48 71076 WFT2940 N Nickel 29 x 40 71077 WFT2948 N Nickel 29 x 48 71080 WFT3340 N Nickel 33 x 40 71081 WFT3348 N Nickel 33 x 48 Accessories Model...

Page 22: ...22 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL 2013 2014 2015 Innovative Hearth Products LLC 1508 Elm Hill Pike Suite 108 Nashville TN 37210...

Page 23: ...a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning d...

Page 24: ...________________________________________________ Your Dealer s Name__________________________________________________ 4 The description of the part 5 The quantity required 6 The installation date of t...

Reviews: