background image

INSTALLATION AND OPERATION MANUAL

     

WARNING

 

Hot! Do not touch!  The glass and surfaces of this appliance will 

be hot during operation and will retain heat for a while after 

shutting off the appliance.   Severe burns may result. 

• 

 

Carefully supervise children in the same room as appliance.

Save These Instructions 

For Future Reference

Wood Stoves

Model Canyon™  ST310

Free-Standing 

EPA Certified

Wood-Burning Stoves

P/N 900133-00, REV. NC, 12/2013

A French manual is available upon request. Order P/N 900134-00.

Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de 

la pièce 900134-00.

This appliance must be properly installed and operated in order to prevent the 

possibility of a house fire. Please read this entire installation and operation 

manual before installing and using your wood stove. Failure to follow 

these instructions could result in property damage, bodily injury or 

even death. Contact your local building or fire officials to obtain 

a permit and information on any installation requirements 

and inspection requirements in your area.

US

Portland

Report # 050-S-09b-2

P900133-00

12

/16

/20

13

Summary of Contents for Canyon ST310

Page 1: ...ch manual is available upon request Order P N 900134 00 Ce manuel d installation est disponible en francais simplement en faire la demande Num ro de la pi ce 900134 00 This appliance must be properly...

Page 2: ...roper Venting System 4 Negative Pressure Warning 5 Creosote 5 Disposal of Ashes 5 Fuel 5 Paint Curing 5 Burn In Period 5 Clearances to Combustibles 6 7 Floor Protection 6 7 Alcove Clearances 6 Chimney...

Page 3: ...during the burn ing season to check for soot and creosote accumulations Any accumulations over 1 8 thick should be removed by a professionalchimneysweep Donotattempttoburnoutheavy creosoteaccumulation...

Page 4: ...he connected appliance in accordance with the manufacturer s instructions Chimney Guidelines This appliance requires approximately 12 feet minimum of effective draw provided by the venting system As a...

Page 5: ...reate dangerous back drafting of the stove and chimney joints drawing combustion by products into the home Be sure your home has adequate makeup air to eliminate negative pressures caused by the above...

Page 6: ...nd the total vent length above the flue outlet exceeds 14 feet it is recommended that the 8 to 6 pipe reducer is used and a 6 venting system be installed This appliance may be vented into a code appro...

Page 7: ...l distances should be measured from the stove s flue collar 2 Minimum noncombustible hearth pad dimensions 3 Not applicable to alcove installations 4 In corner applications when installed at minimum b...

Page 8: ...r Figure 5 Typical Installation Figure 6 Connected to a Masonry Chimney Floor Protector Floor Protector Fasten each stove pipe connection with at least 3 sheet metal screws Single wall stove pipe must...

Page 9: ...ermination All mobile home installa tions require an outside air kit see Page 27 for ordering information and the stove must be secured to the floor and grounded to the mobile home chassis Install Out...

Page 10: ...ll be 12 in 305 mm Chimney section concentric with and spaced 1 in 25 4 mm away from connector by means of sheet steel support plates on both ends of chimney section Opening shall be covered and chimn...

Page 11: ...nd remove the contents upon receipt and check for any damaged or missing parts If there is hidden damage notify your freight company or IHP dealer immediately CAUTION Wear gloves during installation i...

Page 12: ...asher and screw in that leg as well 9 Install bricks and baffle as per instructions on Pages 14 and 15 It is highly recommended that the baffle be assembled before the chimney is installed so that the...

Page 13: ...le s center should be 3 76 mm directly forward from the center of the flue outlet or locate as per the instructions below 6 Position the stove on your floor protection in the exact location where it i...

Page 14: ...nit Once you have the first two boards installed slide the board to the left side of the baffle support all the way to the left and rear of the unit You will slide the board to the right side of the s...

Page 15: ...X 8 3 4 B 6 1 2 X 4 1 2 C 3 1 2 X 9 D 1 1 2 X 4 1 2 E 3 7 8 X 9 F 4 1 2 X 9 H 3 1 2 X 4 1 2 K 3 X 7 M 4 1 2 X 4 1 2 Figure 14 26 B 27 B 28 M 29 B 30 B 1 F 2 F 3 F 4 F 5 F 6 F 7 F 8 F 9 E 31 A 32 A 34...

Page 16: ...nsure you are not over firing your appliance and it will also ensure you are burning fuel at a rate that is most efficient Place a stove thermometer on the top of the appliance Monitor the temperature...

Page 17: ...ensure uninterrupted blower operation For example a small fire may require a slower blower speed to keep the heat output by the blower consistent If the blower is operated in manual mode it may be ne...

Page 18: ...ool down to 275 to 400 degrees on Elites locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the stove wi...

Page 19: ...pulling up while holding the op posite side of the door Lift door out of the lower hinge pin and place face down on a soft surface Step 2 Remove Door Back Screws 6 ea Using a 5 32 allen wrench remove...

Page 20: ...lass on Page 19 SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blankets are pushed back flush with the front...

Page 21: ...fle assembly DO NOT Close the door tightly during Burn In Period DO Be sure to clean any fingerprints from optional accessories that have plated surfaces before burning the appliance Clean the plated...

Page 22: ...astener Kit 23 71117 Bottom Heatshield 24 H5662 Cascade Olympic Leg Kit Outside Air Plenum Box Contact an IHP dealer to obtain any of these parts Never use substitute materials Use of non approved par...

Page 23: ...NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts Model ST310 34 47 48 49 33 35 41 41 39 39 39 42 39 39 39 39 39 39 39 39 39 39 38 37 41 41 39 39 39 42 36 43 45 43 44 39 39 44 40 40 46 40...

Page 24: ...24 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts Model ST310 Door Parts Blower Parts 25 29 31 28 27 26 32 30 7 11 10 6 9 5 4 4 1 8 2 3...

Page 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts Model ST310 22 24 18 20 21 23 Leg and Leg Parts...

Page 26: ...26 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE Replacement Parts Model ST310 15 18 15 18 19 16 17 19 Ash Drawer Pedestal and Pedestal...

Page 27: ...DLE AND NAMEPLATE F1870 TRAD FPK BG LG Large Traditional Faceplate Kit Brushed Gold F1869 TRAD FPK G LG Large Traditional Faceplate Kit Gold BLOWER H7917 BLWR FSB700 SS Blower Kit FS Woodstoves OUTSID...

Page 28: ...28 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL eNGLISH 2013 2014 2015 Innovative Hearth Products LLC 1502 14th St NW Auburn WA USA 98001...

Page 29: ...29 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE SAFETY LISTING LABEL FRENCH Innovative Hearth Products LLC 1502 14th St NW Auburn WA USA 98001...

Page 30: ...30 NOTES...

Page 31: ...a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning d...

Page 32: ...ment parts See Pages 22 through 26 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts...

Reviews: