page 12
Z-397 WEB
www.ironlogic.me
Ethernet bridge mode configuration example.
- Z-397 WEB converter .....1
- USB cable AM-BM ........1
- Software CD ..................1
Ambient temperature: 5°C
…
40°C
Humidity: Not exceeding 80% at 25°C
The reader should not be operated where the following exists: atmospheric precipitation, direct
sunlight, sand, dust and moisture condensation.
Reader specifications may not fully be as specified, when operating under non-recommended
conditions.
This device is covered by a limited warranty for 24 months from the date of sale.
The warranty becomes void if:
- This Manual is not followed;
- Device has physical damage;
- Device has visible traces of exposure to moisture and aggressive chemicals;
- Device circuits have visible traces of being tampered with by unauthorised parties.
Under active warranty, the Manufacturer will repair the device or replace any broken parts, FREE of
charge, if the fault is caused by manufacturing defect.
7. PACKAGE CONTENTS
8. OPERATING CONDITIONS
9. LIMITED WARRANTY
Conv erter
№
1 (
Сервер
)
Converter
№
2 (
Клиент
)
[COMMON]
MODE=SERVER
[NETWORK]
USE_DHCP=0
LOCAL_IP=192.168.1.100
SUBNET MASK=255.255.255.0
GAT EWAY=192.168.1.1
DNS=192.168.1.1
…
[CVT_SERVER]
LINE1_PORT=1000
LINE2_PORT=1001
LINE1_ALLOWED_IP=255.255.255.255
LINE2_ALLOWED_IP=255.255.255.255
…
[RS485]
LINE1_BAUD=19200
LINE2_BAUD=19200
[COMMON]
MODE=CLIENT
[NETWORK]
USE_DHCP=1
…
[CVT_ CLIENT]
LINE1_REMOTE_ADDR=192.168.1.100
LINE2_REMOTE_ADDR=192.168.1.100
LINE1_REMOTE_PORT=1000
LINE1_REMOTE_PORT=1001
…
[RS485]
LINE1_BAUD=19200
LINE2_BAUD=57600