background image

To go forward with the erase, touch and hold the Master card: the LED will slowly blink red, then will 

flash green once, to acknowledge that all cards, including the Master card, have been erased.

After that, the device will revert into normal operation and indicate its current operation mode by 

solid indication of one of three LED colours.
Note: After all cards have been erased, the first card that touches the device 

will be assigned as a

 

Master card.

6.5

   

Setting  the  Timer

    *Function  is  under  construction,  for  details  contact 

[email protected]

While the LED is blinking yellow, please take away the Master card from the reader. The LED starts 
to blink twice more often, indicating that the reader is ready to set the release timer. The current 
timer setting will now be displayed.

Timer values are measured in hours (from 0 to 8) and tens of minutes (0, 10, 20, 30, 40, 50). They 

are shown as series of LED flashes. Red flashes correspond to hours and green flashes to 10-
minute units. Single yellow flashes separate the series of red flashes and green flashes.

An example of timer display may look like this (R  red flash, G  green flash, Y  yellow flash):
Y RR Y G … (same sequence is then repeated). 2 red flashes stand for 2 hours and 1 green flash 

stands for 1 10-minute unit. Total time is 2 hours 10 minutes.

Changing timer value requires a Master card and an Access card. Hours are changed by the 

Master card and Minutes are changed by the Access Card.

First touch by each of these cards resets corresponding unit to 0. After that, the hours are set by 

desired number of Master card touches, and the 10-minutes units   by desired number of Access 
card touches. The increments are cyclic, after the maximum value for this unit it will reset to zero and 
increment again.

Each card touch changes either red flash number or green flash number. Yellow 

flashes

 still work 

as separators between the red and green ones.

After 20 s without any card touches, the device will exit the timer value programming (storing the 

new timer value). 

    7.  ADDITIONAL INFORMATION

1. After the device has been mounted and connected to the mains power (220 V AC), the LED 

indicator runs indicate self-diagnostic: for 3 s it shines solid yellow. Then LED changes display 
accordingly to selected operation mode.

2. The Master card is used only for device programming and never for access control. Only one 

Master card exists. 

3. In the delivery package, six cards are found, initially all already pre-stored to device card 

database: one coloured (assigned Master card) and five whites (assigned Access cards). After 
Erase All Cards operation, the first card that touches the reader is stored as the Master card. To 
prepare device for use, at least one Access card must be added as well. 

4. After 

the power supply

 was lost and later restored, the chosen operation mode and all the 

settings are retained.

5. Before external devices are to be connected to the power relay outputs in Switch and Timer 

modes, please check that the initial contacts state is correct (closed or open).

In Energy Pocket mode, the contacts state always corresponds to one described in paragraph 4.

page 

4

MATRIX

 

III 220

www.ironlogic.

me

Summary of Contents for Matrix III 220

Page 1: ...ing and property maintenance and decoration works etc Master cards are used to program the device Access cards are used to operate the device A card becomes a Master card or an Access card during its programming 2 SPECIFICATIONS Supply voltage 220 V Consumption current 35 mA Power relay circuit current max 6A Power relay circuit voltage max 250 V Reader working frequency 125 kHz Cards standard EM ...

Page 2: ...er the contacts are closed no longer than the Release Interval programmed with a Master card Device has 3 programming modes Add Access card Erase All Cards and Release Interval Setup 4 CABLES PURPOSE Power Supply Cable 2 wires Power Relay Control Cable 3 wires page 2 Wire Colour Purpose 1 Brown 220 V AC 2 Blue 220 V AC Wire Colour Purpose 1 Brown NC Norm ally Closed 2 Black Mix COM Com mon 3 Blue ...

Page 3: ...ges into blinking yellow indicating Release Timer Setup Mode In further 5 s the blinking stops and the device returns to its normal operation the LED will become solid and its colour will indicate one of the three Operation Modes selected in paragraph 6 1 Holding the Master card further will repeat the cycle through the programming modes described above Blinking green Blinking red Blinking yellow ...

Page 4: ...Pocket mode the contacts state always corresponds to one described in paragraph 4 To go forward with the erase touch and hold the Master card the LED will slowly blink red then will flash green once to acknowledge that all cards including the Master card have been erased After that the device will revert into normal operation and indicate its current operation mode by solid indication of one of th...

Page 5: ...ric precipitation direct sunlight sand dust and moisture condensation 10 LIMITED WARRANTY This device is covered by a limited warranty for 24 months The warranty becomes void if This Manual is not followed Device has physical damage Device has visible traces of exposure to moisture and aggressive chemicals Device circuits have visible traces of being tampered with by unauthorised parties Under act...

Page 6: ... E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me page 6 MATRIX III 220 www ironlogic me The symbol of crossed throught waste bin on wheels means that the product must be disposed of at f separate collection point This also applies to the product and all accessories marked with this symbol Products labeled as such must not be disposed of with normal ho...

Reviews: