To go forward with the erase, touch and hold the Master card: the LED will slowly blink red, then will
flash green once, to acknowledge that all cards, including the Master card, have been erased.
After that, the device will revert into normal operation and indicate its current operation mode by
solid indication of one of three LED colours.
Note: After all cards have been erased, the first card that touches the device
will be assigned as a
Master card.
6.5
Setting the Timer
*Function is under construction, for details contact
While the LED is blinking yellow, please take away the Master card from the reader. The LED starts
to blink twice more often, indicating that the reader is ready to set the release timer. The current
timer setting will now be displayed.
Timer values are measured in hours (from 0 to 8) and tens of minutes (0, 10, 20, 30, 40, 50). They
are shown as series of LED flashes. Red flashes correspond to hours and green flashes to 10-
minute units. Single yellow flashes separate the series of red flashes and green flashes.
An example of timer display may look like this (R red flash, G green flash, Y yellow flash):
Y RR Y G … (same sequence is then repeated). 2 red flashes stand for 2 hours and 1 green flash
stands for 1 10-minute unit. Total time is 2 hours 10 minutes.
Changing timer value requires a Master card and an Access card. Hours are changed by the
Master card and Minutes are changed by the Access Card.
First touch by each of these cards resets corresponding unit to 0. After that, the hours are set by
desired number of Master card touches, and the 10-minutes units by desired number of Access
card touches. The increments are cyclic, after the maximum value for this unit it will reset to zero and
increment again.
Each card touch changes either red flash number or green flash number. Yellow
flashes
still work
as separators between the red and green ones.
After 20 s without any card touches, the device will exit the timer value programming (storing the
new timer value).
7. ADDITIONAL INFORMATION
1. After the device has been mounted and connected to the mains power (220 V AC), the LED
indicator runs indicate self-diagnostic: for 3 s it shines solid yellow. Then LED changes display
accordingly to selected operation mode.
2. The Master card is used only for device programming and never for access control. Only one
Master card exists.
3. In the delivery package, six cards are found, initially all already pre-stored to device card
database: one coloured (assigned Master card) and five whites (assigned Access cards). After
Erase All Cards operation, the first card that touches the reader is stored as the Master card. To
prepare device for use, at least one Access card must be added as well.
4. After
the power supply
was lost and later restored, the chosen operation mode and all the
settings are retained.
5. Before external devices are to be connected to the power relay outputs in Switch and Timer
modes, please check that the initial contacts state is correct (closed or open).
In Energy Pocket mode, the contacts state always corresponds to one described in paragraph 4.
page
4
MATRIX
III 220
www.ironlogic.
me