5.3.2 NATO Cable Installation
WARNING
MAKE SURE INVERTER IS ELECTRICALLY DISCONNECTED FROM 24
VDC POWER SOURCE (NATO PLUG) PRIOR TO SERVICING. FAILURE
TO DISCONNECT INVERTER FROM 24 VDC POWER SOURCE (NATO
PLUG) FIRST MAY RESULT IN FIRE, SEVERE ELECTRIC SHOCK, OR
DEATH.
CAUTION
Make sure cable is connected properly: positive (+), red wire to left post
and negative (-), black wire to right post. Connecting cable improperly
may result in internal damage to inverter.
CAUTION
If you are installing the NATO Cable for the first time, install the red
terminal cover on the red lead and the black terminal cover on the black
lead.
Install the NATO Cable to the inverter and the vehicle as follows:
7.
Make sure inverter power switch on control panel is in off ('O') position.
8.
Make sure NATO Cable is disconnected from 24 VDC power source
.
9. Connect positive (+), red lead to left post on inverter and negative (-), black lead to
right post.
10. Secure cable to inverter using nuts and lock washers. Tighten nuts until snug.
11. Verify cable is connected properly by having a second person verify connections.
12. Connect NATO Cable to 24 VDC power source.