background image

2

Front View

Bottom View

Rear View

Hardware Information

Mirror

Up / Down Tilt Buttons

Face Camera Flash

Proximity Sensor

4.3” Color Touch Screen LCD

Cable Channel

Knock-out

Function Buttons

USB Connector / Screw CAP

Face Camera

Alignment Guide

Smart Card Reader (optional)

Speaker

Status LED

Tripod Socket
(1/4-20 (1/4 diameter, 20 threads per inch))

Surface Mounting
Screw Hole

Gang Box Screw Hole

CCTV Camera (optional)
MIC / Screw Cap

Function Buttons

Tamper Switch

Desktop Stand Hole

Installation Plate

Camera Unit

Interface Panel

Summary of Contents for IrisAccess iCAM7100 Series

Page 1: ...ftware Required Software for desired system type IrisAccess EAC iData SDK etc What s in the Box iCAM7100 series Hardware Guide L wrench iCAM7100 series Hardware Guide ISO ANSI COMPLIANT CONTACTLESS CARD READER FACE CAMERA DUAL IRIS 4 3 LCD EASY INSTALLATION iCAM7000 SERIES HARDWARE GUIDE ADVANCED IRIS RECOGNITION FACE CAPTURE SYSTEM Fully automatic fast dual iris capture Easy non intrusive user in...

Page 2: ...l Knock out Function Buttons USB Connector Screw CAP Face Camera Alignment Guide Smart Card Reader optional Speaker Status LED Tripod Socket 1 4 20 1 4 diameter 20 threads per inch Surface Mounting Screw Hole Gang Box Screw Hole CCTV Camera optional MIC Screw Cap Function Buttons Tamper Switch Desktop Stand Hole Installation Plate Camera Unit Interface Panel ...

Page 3: ... Wiring Legend Guide Rear View Installation Plate Screw RTC Battery Fuse Power LED Factory Default Button Power Connection On Off Switch Ethernet Connection Extra Fuse Input Output Connections Tamper Switch Extra Fuse Wiring Legend Guide ...

Page 4: ...rd Party enclosure may be used to protect the unit from exposure to dust moisture and extreme temperatures See www irisid com Support Service for more information Installation in a extreme environment without proper protection may cause permanent damage and void your warranty The recommended mounting height for the iCAM7100 series is 138cm 54 3inches from the floor to the bottom of the unit This m...

Page 5: ...box recess mount with optional recess mounting kit or optional desktop stand Surface Mounting After opening the interface panel loosen the screw Unscrew the installation plate screw to seperate from the installation plate Seperate the installation plate by sliding the plate downward 3 Cover Rear Installation Plate The iCAM can be surface mounted with standard equipment provided with the contents o...

Page 6: ...d wiring through the installation plate hole i e Power Ethernet etc Attach the installation plate to the wall surface using the appropriate fastener recommended 10 screws and anchors for the wall material Another option is to mount and fasten the installation plate to a previously installed electrical gang box 4 Installation Plate Surface Mount Gang Box Mount Hole Marking Installation Plate ...

Page 7: ... 9 Remove protective film from RTC battery 6 Before wiring unit confirm the power is in the off position Route and connect the Power and Ethernet wires to iCAM7100 series 7 NOTE OFF ON Remove the coin battery protect film OFF ON OFF ON Power on Power Supply Connector Ethernet Cable OFF ON If connecting any other wiring such as Wiegand GPI O to the iCAM review the following section Wire Connection ...

Page 8: ...elay is activated when the iCAM tamper switch is triggered The maximum electrical rating for the relay is 3A at 24VDC IMPORTANT ONLY KNOWLEDGEABLE PROFESSIONAL INSTALLERS SHOULD BE USED TO INSTALL ALL ELECTRONIC ENTRY EXIT LOCKING DEVICES DIRECT CONNECTION OF ELECTRONIC ENTRY EXIT LOCKING DEVICES SHOULDN T BE MADE FROM THE RELAY OUTPUTS ON THE ICAM IT IS THE RESPONSIBILITY OF THE INSTALLER TO ASSU...

Page 9: ...GPIO3 GND GPIO4 GND GROUND DATA_1 DATA_0 GPIO3 GROUND GPIO4 GROUND Wiegand Output NC DATA_0 DATA_1 GND Card Reader Interface Up Down 5IF 8JFHBOE 0VUQVU GSPN UIF J TFSJFT DBNFSB VOJU DBO CF VTFE XJUI SE QBSUZ EFWJDFT DBQBCMF PG SFDFJWJOH 8JFHBOE EBUB 5IJT 8JFHBOE PVUQVU FNVMBUFT B UZQJDBM DDFTT POUSPM BSE 3FBEFS POGJHVSBUJPO PG UIJT PVUQVU JT QSPWJEFE UISPVHI TPGUXBSF 4FF UIF BTTPDJBUFE JNBHF GPS H...

Page 10: ...ial RS232 communications This connection can provide 12VDC and a maximum of 500mA current to a smart card reader RS422 Output E RS422 Output To RS422 port of computer or access system RXD_P RXD_N TXD_P TXD_N RXD_P RXD_N TXD_P TXD_N RS422 serial communication port for connection with an access panel or to other computer equipment When configured the Card ID associated with the user is output from t...

Page 11: ...ternet browser To login the User ID required when prompted is iCAM7000 The Password is iris7000 The system is case sensitive when entering in your login credentials Once you have connected to the iCAM Configuration Interface settings information and options become available to further configure your system Additional documentation for setup and configuration can be found at http irisid com ss docu...

Page 12: ... DBSE JT QSFTFOUFE o 1JDUVSF DBQUVSF SBOHF JT _ JODIFT DN BXBZ o 4FMG PS BVUP TFU IFJHIU BEKVTUNFOU o 1MBDJOH EPU PWFS UIF CSJEHF PG OPTF FBTJMZ IFMQT BMJHONFOU Green dot In range Orange dot Out of range 31 35cm Tilt up 35 Degrees Read distance 14inches Tilt down 25 Degrees Read distance 14inches away 12 14 The on unit up down tilt buttons can be used to adjust the tilt angle or an external mounte...

Page 13: ...DBUFE JOTJEF PG UIF VOJU CFMPX UIF 35 CBUUFSZ TFF JNBHF BOE DBO CF VTFE JO UXP EJGGFSFOU XBZT Factory Default Button 1 IP ADDRESS DEFAULT Resets the IP Address to Factory Default NOTE OZ JOGPSNBUJPO VQMPBEFE JOGPSNBUJPO JODMVEJOH GJSNXBSF VQEBUFT UP UIF VOJU UIBU NBZ IBWF CFFO QFSGPSNFE QSJPS UP UIJT SFTFU GVODUJPO NBZ CF DMFBSFE MM TFUUJOHT XJMM CF GBDUPSZ SFTUPSFE UP UIF EFGBVMU MFWFM o 8IJMF QP...

Page 14: ...PERFORMED WITHOUT POWER CONNECTED TO THE UNIT Fuse Specification 1 Fuse Replacement Remove the screws to release the Wiring Legend Guide 2 Use tweezers and replace the Fuse Littlefuse Manufacturer 0451 004 MRL Part No 4A Ampere Rating The iCAM7100 series camera unit s contains a replaceable fuse which protects the unit s from excessive current consumption In the event that the iCAM7100 series unit...

Page 15: ...15 Memo Serial Number Unit IP Address Installation Date Note ...

Page 16: ...er Input 4 3 diagonal 480 x 272 pixels Touch Screen LCD Pop up on screen pin pad Pin Pad High output flash for face capture Flash Face camera CMOS 5MP Face Image Camera Secure user accessible USB port External Media Device Connectivity 32 F 113 F 0 C 45 C Operating Temperature 4 F 203 F 20 C 95 C Storage Temperature Up to 90 non condensing Humidity Control for user defined operations Relays x 2 Th...

Reviews: