 Therapeutic Wearable System™

TENS + EMS Wireless Muscle Stimulator

Instruction Manual

M O D E L   N O .   E T - 5 0 5 0

Summary of Contents for PlayMakar

Page 1: ...Therapeutic Wearable System TENS EMS Wireless Muscle Stimulator Instruction Manual M O D E L N O E T 5 0 5 0 ...

Page 2: ...s Choose TENS Modes P1 through P7 Symptomatic relief and management of chronic intractable pain and relief of pain associated with arthritis Choose TENS Mode P8 Use by healthy adults for the stimulation of healthy muscles in order to improve or facilitate muscle performance Choose EMS Modes P1 through P6 WHAT YOUR SYSTEM INCLUDES 1 Wireless Hand Remote x 1 2 Wireless Receiver Pods CH1 CH2 x 2 3 Se...

Page 3: ...Placement of Electrode Pads Operation of Remote Control Operation of Wireless Receiver Pod s Communication between Remote and Receiver Pod s Selecting a Program Selecting Therapy Time Selecting the Therapy Intensity Level CARE AND MAINTENANCE 26 TROUBLESHOOTING 28 TECHNICAL SPECIFICATIONS 29 RADIO FREQUENCY WIRELESS INFORMATION 32 CONFORMITY OF STANDARDS 33 INFORMATION ABOUT ELECTROMAGNETIC COMPAT...

Page 4: ...to stimulate healthy muscle in order to improve muscle strength and performance Indications for Use The Therapeutic Wearable System is a digital electrical stimulator for active treatment as per the following intended use for temporary relief of pain associated with sore and aching muscles in the lower back due to strain from exercise or normal household and work activities Choose TENS Modes P1 th...

Page 5: ...r place electrode pads over areas where drugs medicines are administered short term or long term by injection e g hormone treatment Do not use if you have epilepsy Do not use if you have recently undergone a surgical procedure Do not use following acute trauma or fracture in case of critical ischemia of the limbs WARNINGS AND PRECAUTIONS Warnings If you are under the care of a Physician consult wi...

Page 6: ...h could be lethal Do not use electrode pads over or close to cancerous lesions Use the electrode pads only on normal healthy clean and dry skin Do not use the electrode pads on open wounds rashes or over swollen red infected or inflamed skin If you have ever had back surgery consult your Physician before using this system Electronic monitoring equipment such as ECG and ECG alarms may not operate p...

Page 7: ...The effectiveness of the system depends greatly on a person s individual physical condition It may not always be effective for every user The safety of neuromuscular stimulation during pregnancy has not been established Use caution when and or if Sensory nerve damage is present by a loss of normal skin sensation Use caution prior to using this device on patients suspected of having heart disease U...

Page 8: ...ment efficacy and the use of cold packs on treated muscles after treatment is likewise recommended This unit should only be used with iReliev brand electrode pads and accessories The device is not intended for medical use for the treatment of any medical condition or for any per manent physical changes Contact ExcelHealth Inc or an authorized reseller if your unit is not working correctly Do not u...

Page 9: ...ur system and consult your Physician If skin under one or more electrode pads feels irritated after using the stimulator for a long period of time use the stimulator for a shorter period of time Minor redness at stimulation placement is a normal skin reaction It is not considered as skin irritation and it will normally disappear within 30 minutes after the electrode pads are removed If the redness...

Page 10: ...ribed by your practitioner This device is for external use only Choking may result from a child swallowing a small part that has become detached from the device Note If you have any doubt or have medical questions about using this system please consult your doctor Electrode Pad Precautions To reposition the electrode pads during a session always pause the program currently running reposi tion the ...

Page 11: ...utput performance and safety may be affect ed greatly in extreme humidity Therefore it is very important to keep the system device s dry to ensure the safety and performance of the stimulator User of this system must be at least 16 years old This system is for indoor home use This system may be used daily with no operation time limit but it is recommended to not exceed 60 minutes per day If there ...

Page 12: ...USB Charging Cable x 1 Length 23 5 in 5 AC Adaptor x 1 6 Carry Case x 1 About Remote Control 1 Power ON key 2 SET key 3 Power OFF key 4 CH key 5 ON key increase 6 OFF key decrease 7 USB Charger Socket About Receiver Pods 8 CH1 Receiver Pod Power ON OFF key 9 CH2 Receiver Pod Power ON OFF key 10 Snaps for Electrode Pad 11 USB Charger Socket 12 www iReliev com ...

Page 13: ... disappear Charging the Receiver Pod Using the AC Adaptor 1 Connect the small end of the USB cable to the receiver pod and the other end into the AC adaptor 2 Plug the adaptor into any standard wall outlet An orange light indicates the receiver pod is now in charge mode once fully charged the orange light will turn off Note You may not use the handheld remote while it s charging When charging the ...

Page 14: ...Remote Battery Status Remote ON Remote Low Battery Remote Battery Drained Battery Symbol Showing Remote Charging Remote Done Charging Battery Symbol Showing NO Battery Symbol Showing 14 www iReliev com ...

Page 15: ...ceiver Pod Battery Status Receiver Pod ON Receiver Pod Low Battery Receiver Pod Battery Drained Light Blinking Receiver Pod Charging Receiver Pod Done Charging Orange Light On Light Off 15 www iReliev com ...

Page 16: ... them fall causing a strong impact heavy blow etc Do not use sharp utensils or metal objects to scratch or puncture the battery Do not place the battery in a microwave oven or dryer Do not place the battery into high pressure or high temperature environments Do not mix this product with other brands or other types of batteries Before charging or discharging the battery read the manual Stay away fr...

Page 17: ...lcohol Rinse and dry thoroughly 3 Trim excess body hair from the area with scissors do not shave 4 Optionally apply skin prep to the area to form a protective barrier on your skin Apply let dry and affix electrode pad as directed This will both reduce the chance of skin irritation and may extend the life of your electrode pads 5 When removing electrode pads always remove by pulling in the directio...

Page 18: ...18 www iReliev com ...

Page 19: ...e arms or legs bear in mind that the muscle contraction may cause involuntary limb movement which could cause injury to you or others Always ensure the limb is secured to prevent movement Receiver Pod Operation Turning Receiver Pod On Off 1 To turn on the receiver pod press the power button 2 Blue backlight will be lit up lasting for 60 seconds and then the back light will turn off with no activit...

Page 20: ...hased with your ET 5050 system Channel 3 and Channel 4 receiver pods CH3 and CH4 are available for replacement purposes as well as extending therapy use up to 4 channels at one time Please contact ExcelHealth authorized resellers or visit us at www iReliev com 3 Whenever the receiver pods are powered on the remote control unit shall display the channel of the receiver pod s with CH1 CH2 and or CH3...

Page 21: ... 2 LED in blue blinks on with the channel in use when it receives signal transmitting from the remote 3 If LED in orange is flashing battery power is low Receiver pod will turn on when charging the battery Orange light will remain until fully charged then turns off 21 www iReliev com 1 Power OFF Adjust Decrease Key 2 Navigation Key Program Set 3 Power ON Adjust Increase Key 4 Program Mode 5 Therap...

Page 22: ... Choose the mode that is appropriate to your needs or gives you the greatest pleasure How to Select TENS EMS Mode 1 Press SET button the preset default therapy mode TENS EMS will flash on the display Use the ON or OFF button if you would like to change the therapy mode 2 Press SET button again The numeric number of the pro gram will then flash 3 Press the ON button to increase or the OFF button to...

Page 23: ...due to strain from exercise or normal household and work activities Continuous comfortable tingling The underlying pain should decrease gradually after treatment P2 Comfortable pulsing sensation The underlying pain should decrease almost immediately P3 Comfortable pulsing sensation The underlying pain should decrease almost immediately P4 Variable comfortable tingling and pulsing sensation sensati...

Page 24: ...ws down during the session It feels like a tapping massage but softer than P2 Use it after intense exercise to promote recovery and relaxation 20 min duration P4 Active Recovery This program activates the muscle in a short contraction relaxation cycle It feels like a kneading massage smoother than P2 P3 Use it after intense exercise to promote recovery and relaxation 20 min duration P5 Build Endur...

Page 25: ...increase or the OFF button to decrease repeatedly until the desired duration appears on the display 3 The treatment time you selected will appear on the display the next time you turn the device on Note If you change programs during the course of a therapy session the treatment time will not set unless you manually reset it by performing the steps de scribed above 25 www iReliev com ...

Page 26: ...eset to 0 for safety reasons CARE MAINTENANCE Remote and Receiver Pods To clean exterior of system please lightly wipe with a clean wet cloth Do not submerge the stimulator in liq uids or expose it to large amounts of water If the user s area has any pets or pests the system device s should be cleaned each time before use and kept safe away in a drawer or somewhere pets and children won t be able ...

Page 27: ...at www iReliev com or contact authorized distributor s Rechargeable Battery The rechargeable battery is built in the device s Please do not attempt to disassemble or force open the built in battery Batteries have a finite lifetime of 12 months with approximately 300 cycle times To maximize bat tery life please charge the system every 3 months when not in use When the battery is fully charged it is...

Page 28: ...shes continuously Charge the receiver pod s or it will turn off automatically The remote and or receiver pod s do not seem to be charging Ensure the USB cable is correctly plugged into the remote receiver pod s and firmly plugged into the AC adaptor and into the electrical socket on the other side Receiver pod s does not pair with remote The remote does not control receiver pod s well Make sure th...

Page 29: ...mode Timer 5 60 min adjustable Wave Form Symmetrical bi phasic square pulse Max Charge per Pulse 20 8 microcoulombs maximum Essential Performance The stimulation output as defined in the following specification table for TENS EMS TENS Programs Program Pulse width uS Frequency Hz Function Mode P1 260 15 Constant P2 260 60 Burst P3 260 60 Constant P4 260 156 2 60 Modulation P5 260 156 60 Modulation ...

Page 30: ...or I P 100 240Vac 50 60Hz 0 3 0 15A O P 5Vdc 1 2A Weight Dimension Remote Control 60 grams battery included 156 98 x 47 x 15 50 mm Receiver Pod 30 grams battery included 60 x 60 x 15 65 mm Operating Conditions 50 F 10 C to 104 F 40 C 40 90 max Relative humidity Transport and Storage Conditions 14 F 10 C to 140 60 C 30 95 max Relative humidity Operation Altitude 3000m Operating Atmospheric Pressure...

Page 31: ...ng in accordance with FCC rules This symbol means Serial number on the back of the remote This symbol means Lot number on the back of the receiver pod This symbols means Attention consult the accompanying documents Follow instructions for use This symbol means Manufacturer This symbol means type BF equipment this device offers protection against electrical shock by standard compliance to leakage c...

Page 32: ... 2 4GHz ISM Protocol type Proprietary frequency Channel 1 Channel width 1MHz Frequency modulation GFSK Frequency deviation 50KHz EIRP Measured max 4 9 dBM 0 dBM configured as maximum output power Effective emission power 0dBm Data rate 1Mbps Quality of service requirement 9 8 feet range between remote and receiver pod Wireless Security Measures Device Identification 8 bits shared only with other P...

Page 33: ...m other devices If the PlayMakar Therapeutic Wearable System s RF channel is interfered by emission from other devices fail safe outcome is that iReliev s remote control will not operate and or reset the stimulation level to 0 the receiver pods will stop stimulation Interference from other RF wireless and mobile communication devices is possible Refer to Table 1 for recommended distance be tween i...

Page 34: ...extremely low and in all probability do not cause any interfer ence with other devices in the proximity It is recommended that you do not place the device on top of or close to other electronic devices Should you notice any interference with other electrical devices move the device or connect it to a dif ferent socket Radio equipment may affect the operation of this device ELECTROMAGNETIC COMPATIB...

Page 35: ...stem is intended for use in the electromagnetic environment specified below The customer or the user of the PlayMakar Therapeutic Wearable System should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Conducted RF IEC 61000 4 6 3 Vrms 150 kHz to 80 MHz 6V Portable and mobile RF communications equipment should be...

Page 36: ...s power quality should be that of a typical commercial or hospital environ ment Surge IEC 61000 4 5 1 kV differential mode 2 kV common mode 1 kV differential mode Mains power quality should be that of a typical commercial or hospital environ ment Voltage dips short interrup tions and volt age variations on power sup ply input lines IEC 61000 4 11 0 UT 0 5 cycle At 0o 45o 90o 135o 180o 225o 270o an...

Page 37: ...stem should assure that it is used in such an environ ment Emissions test Compliance Electromagnetic environment guidance CE emissions CISPR11 Group 1 The PlayMakar Therapeutic Wearable System uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RE emissions CISPR11 Class B The PlayMakar Th...

Page 38: ...d on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver pod Connect the equipment into an outlet on a circuit different from that to which the receiver pod is connected Consult the dealer or an experienced radio TV technician for help The user should...

Page 39: ...lectrode pads and other accessories are guaranteed to be free from defects in workmanship and materials at the time of delivery The warranty does not apply to damage resulting from failure to follow the operating instructions accidents abuse alterations or disassembly by unauthorized individuals ExcelHealth reserves the right to replace or repair the unit at their discretion US Tel no 855 723 2582...

Page 40: ...istering your device flip it as shown to reveal serial number Enter serial number on the warranty registration form or complete warranty on the following page Please send registration card within 14 days of purchase in a stamped envelope All iReliev devices have separate serial numbers OTHER PLAYMAKAR ACCESSORIES FROM YOUR LOCAL RETAILER 40 www iReliev com Wireless Pads Refill Kit The iReliev Wire...

Page 41: ...41 www iReliev com ...

Page 42: ......

Page 43: ......

Page 44: ...v com 1603 Hart Street Southlake TX 76092 If you have any questions whatsoever regarding your PlayMakar Therapeutic Wearable System Model ET 5050 contact your reseller or ExcelHealth Inc at 855 723 2582 or visit www iReliev com ...