4 - Clearance to Combustible Materials
Clearance to Combustibles
The following clearance data is based on a maximum limit of 90°F (50 °C) plus ambient
temperature.
Note with an ambient temperature of 70
°
F the surface temperatures at the clearance
distances listed below could reach 160°F Care should be taken with placement of plastic
or vinyl in the proximity of the heater as they tend to distort and soften at these
temperatures.
The
INSTALLER
is responsible to ensure that building materials with a low heat tolerance
which may degrade at higher temperatures are protected to prevent degradation.
Installation / Code Requirements
Installation must comply with local building codes and/or, for the USA/National Fuel Gas Code,
ANZI Z 223.1 (NFPA 54) and for Canada, CAN/CGA B149.1 and B149.2, National Gas and
Propane Installation Code (latest editions).
Appliance must be electrically grounded in accordance with local codes or, in their absence; the
National Electrical Code, ANSI/NFPA 70 in the USA, CSA C22.1 Canadian Electrical Code in
Canada.
NOTE
: Some materials deteriorate or soften at sustained temperatures below 160°F.
Consult material manufacturer for recommendations
BELOW
TOP
SIDE
CLEARANCE TO COMBUSTIBLES
22"
MODEL NO.
TOP
SIDES BELOW
33"
18"
GA 301
22"
33"
18"
GA 301 H
22"
33"
18"