2009 NETCONS, s.r.o.
Page 9 of 16
SECNUMBER-ALL
Delete all numbers from security list
SECNUMBER-ALL –
OK
Conf
SECNUMBER?
Request for security list configuration.
SECNUMBER
=(NO),YES,LIST
Conf
Security lists accept only numbers in international syntax:
Example: SE421265440655 means add 421-2-65440655
Example: SECNUMBER-421265440655 means delete 421-2-
65440655
421 is country code in this example and 2 is city code.
6. Command confirmation settings
It is important to make you sure if command was executed successfully when
communicating with IQsocket. For this purpose we implemented notifications of
each executed command. If you activate this notification, you will be informed
about each command execution. In case of SMS commands, you will be notified
by back SMS. In case of managing by phone call, your command will be
confirmed by back phone call to your mobile phone.
6.1 Confirmation settings for SMS commands
Command
Description
Response
Type
SMSCONFIRM=YES
SMS confirmation is turned on for all SMS
commands
SMSCONFIRM=YES –
OK
Conf
SMSCONFIRM=NO
SMS confirmation is turned off for all SMS
commands
SMSCONFIRM=NO –
OK
Conf
SMSCONFIRM?
Request for SMS confirmation settings
SMSCONFIRM=NO,(Y
ES)
Conf
6.2 Confirmation settings for phone calls
Command
Description
Response
Type
RINGCONFIRM=YES
Phone call confirmation is turned on for all
commands. Hang off after 10 seconds
RINGCONFIRM=YES
– OK
Conf
RINGCONFIRM=NO
Phone call confirmation is turned off for all
commands
RINGCONFIRM=NO –
OK
Conf
RINGCONFIRM?
Information message: Request for call
confirmation settings
RINGCONFIRM=NO,(
YES)
Conf
7. Measuring temperature
GSM power socket has built in thermostat. This thermostat enable to measure
temperature of environment and provide it over SMS. It also enables to act as
a temperature regulator to control output power socket or output microrelay
circuit. Device enables to configure two temperature thresholds which control
output power socket. This is just supplemental feature of power socket with
accuracy ± 2 ˚C due to using inexpensive thermostat instead of using
expensive precise external thermostat. This feature cannot replace professional
thermostat.
Command
Description
Response
Type