IQRF GW-GSM-02 User Manual Download Page 9

GW-GSM-02

GW-GSM Tool

GW-GSM Tool is a PC program for setup, operation, testing and debugging of the GSM part of the gateway. It is free to 
download from www.iqrf.or

 

 g/321

 

 .

First steps

Press the power button for at least 3 seconds to wake up the GW (if in sleep mode).

Connect the gateway to PC using a USB cable.

Install 

USB driver – Custom Class

. You can download it from   www.iqrf.org/89. This driver is the same also for other 

IQRF USB devices. See the IQRF Quick start guide   www.iqrf.org/235. If the IQRF IDE or another software using the 
same USB driver (e.g. IQRF UDU) is installed, this step can be omitted.

Run the 

GW-GSM Tool

.

Caution: 

No other program communicating with any IQRF device via USB (e.g. IQRF IDE or IQRF UDU) is allowed to 

run at the same time.

Basic setup

Settings

  –  The tab to configure basic 

gateway functions. 

APN

 – Access Point Name obtained 

from the GSM network operator.

PIN 

- if the SIM card is protected, 

insert the PIN code and press 
Update button

Time

 – Time in 

HH.MM.SS

 format.

Date

 – Date in 

DD.MM.YYYY

 format.

Set Time 

button

 – sets a new time 

to the RTCC. Other settings stay 
unchanged. Once the button is 
pressed, the time and date are 
enabled for editing. Another press 
of the button will launch the RTCC 
with updatded values.

Use SMS Alarm

 – If the box is checked 

the  

Send   SMS

  function   is   enabled. 

Telephone number must be specified in 
the box below.

Use IP filtering

 – If the box is checked the access restriction function is enabled. Only IP addresses listed in 

Safe IPs

 list 

can communicate with the gateway.

Safe IPs

  –  To add a new address to the list, enter the address in the box below the list and press the  

Add

  button. To 

remove an address from the list, select it and press the 

Rem

 button.

Update

 button

 - Updates the configuration of the 

GW-GSM-02.

© 2013  MICRORISC s.r.o.

www.iqrf.org

UG_GW-GSM-02_131016

Page 9

The Settings tab

Summary of Contents for GW-GSM-02

Page 1: ...GW GSM 02 IQRF GSM Gateway Firmware v1 00 User s Guide Preliminary 2013 MICRORISC s r o www iqrf org UG_GW GSM 02_131016 Page 1...

Page 2: ...upgraded from PC Application software for TR module can be uploaded via IQRF IDE4 using the gateway as a programmer Key features TCP Server mode with public IP address SMS alarm feature Data logging I...

Page 3: ...er According to TR module programmable TR module TR 54DA Antenna PCB antenna built in TR module GSM frequency bands 900 MHz or 1800 MHz Antenna External SMA gain 2 15 dBi Flash memory 1 MB serial inte...

Page 4: ...ing two times per second when an error occurred missing SIM card etc IQRF LED red This LED is controlled by the TR module the LEDG output Functionality is fully under control of user application progr...

Page 5: ...ion may precede sending data itself The data is sent only after the TR module executes the startSPI n command Access restriction It is possible to enable IP address filtering If enabled only addresses...

Page 6: ...gth 8 B 0 1 2 3 4 5 6 7 Event System agent GSM RSSI External Power Accumulator voltage Event Type of event see below System Agent Additional information for start up and shutdown events see below GSM...

Page 7: ...cesed remotely by TCP client or localy using USB connectivity Both can be done using GW GSM Tool software Format of the packet containing the temperature is T xx where xx is the temperature in degrees...

Page 8: ...mber Returns all records starting from index number send_data data Sends data to TR module syslog Returns all system records Number is formatted as four digit HEX value with lower case letters Data is...

Page 9: ...s APN Access Point Name obtained from the GSM network operator PIN if the SIM card is protected insert the PIN code and press Update button Time Time in HH MM SS format Date Date in DD MM YYYY format...

Page 10: ...aracter TCP Client TCP client tab to test the gateway IP address of the gateway must be filled in the box above the Connect button When the GW GSM Tool is connected to the gateway via USB cable the IP...

Page 11: ...network Accu Capacity Estimated backup battery life Accu Voltage Actual battery voltage Command window GW status Current command executing by GSM module GW IP Gateway IP address Client IP IP address...

Page 12: ...0 V 240 V AC EU plug Output 5 V DC 500 mA USB A connector cordless CAB USBABMICRO Power supply cord for TY A6 with microUSB output connector Ordering codes GW GSM 02 IQRF GSM gateway Requested option...

Page 13: ...erein are property of their respective owners Legal All information contained in this publication is intended through suggestion only and may be superseded by updates without prior notice No represent...

Reviews: