IQRF GW-GSM-02 User Manual Download Page 4

GW-GSM-02

Hardware

Power supply

GW-GSM-02  is   intended   to   be   supplied   by   external   stabilized   5   V   DC 
connected to micro USB connector.

Accumulator

Backup accumulator is intended especially for short failures of external power 
supply. It is not removable and enables continuous charging when external power is connected.

Power control button (ON / OFF)

Short press (< 3s): no effect

Long press (> 3s): Switching between operational and sleep modes

LED indication

Power LED (red)

Power LED is on when main power is on.

GSM LED (yellow)

Flashes once per second when GSM module is powered.

Flashing twice per second when communicating via GSM/GPRS.

Status LED (green)

Status LED is on when GSM module is establishing connection to network.

Flashing once per two seconds when GSM is logged in the network.

Flashing two times per second when an error occurred (missing SIM card etc.)

IQRF LED (red)

This LED is controlled by the TR module, the LEDG output. Functionality is fully under control of user application program.  
IQRF OS functions dedicated to LEDG can be used. In Demo SW this LED shortly flashes whenever an RF packet is 
transmitted or received by TR module.

MCU

Microcontroller PIC18F26J50 by Microchip is used.

GSM

M590E   dual   band   wireless   module   by   Neoway   is 
used for GSM/GRPS connectivity.

SIM card

SIM   card   with   activated   data   services  from   mobile 
network   operator   must   be   plugged   in   the   SIM 
connector   under   the   cover.   Public  IP   address  is 
required (see below).

IQRF

TR-54DA wireless transceiver module is used for IQRF connectivity. Antenna is built in TR module.

Flash memory

SST25VF080B 1 MB Flash memory by Microchip/SST is used for gateway configuration and message buffer. Up to 
100

 

000 erase/write cycles (typical) is allowed.

© 2013  MICRORISC s.r.o.

www.iqrf.org

UG_GW-GSM-02_131016

Page 4

Summary of Contents for GW-GSM-02

Page 1: ...GW GSM 02 IQRF GSM Gateway Firmware v1 00 User s Guide Preliminary 2013 MICRORISC s r o www iqrf org UG_GW GSM 02_131016 Page 1...

Page 2: ...upgraded from PC Application software for TR module can be uploaded via IQRF IDE4 using the gateway as a programmer Key features TCP Server mode with public IP address SMS alarm feature Data logging I...

Page 3: ...er According to TR module programmable TR module TR 54DA Antenna PCB antenna built in TR module GSM frequency bands 900 MHz or 1800 MHz Antenna External SMA gain 2 15 dBi Flash memory 1 MB serial inte...

Page 4: ...ing two times per second when an error occurred missing SIM card etc IQRF LED red This LED is controlled by the TR module the LEDG output Functionality is fully under control of user application progr...

Page 5: ...ion may precede sending data itself The data is sent only after the TR module executes the startSPI n command Access restriction It is possible to enable IP address filtering If enabled only addresses...

Page 6: ...gth 8 B 0 1 2 3 4 5 6 7 Event System agent GSM RSSI External Power Accumulator voltage Event Type of event see below System Agent Additional information for start up and shutdown events see below GSM...

Page 7: ...cesed remotely by TCP client or localy using USB connectivity Both can be done using GW GSM Tool software Format of the packet containing the temperature is T xx where xx is the temperature in degrees...

Page 8: ...mber Returns all records starting from index number send_data data Sends data to TR module syslog Returns all system records Number is formatted as four digit HEX value with lower case letters Data is...

Page 9: ...s APN Access Point Name obtained from the GSM network operator PIN if the SIM card is protected insert the PIN code and press Update button Time Time in HH MM SS format Date Date in DD MM YYYY format...

Page 10: ...aracter TCP Client TCP client tab to test the gateway IP address of the gateway must be filled in the box above the Connect button When the GW GSM Tool is connected to the gateway via USB cable the IP...

Page 11: ...network Accu Capacity Estimated backup battery life Accu Voltage Actual battery voltage Command window GW status Current command executing by GSM module GW IP Gateway IP address Client IP IP address...

Page 12: ...0 V 240 V AC EU plug Output 5 V DC 500 mA USB A connector cordless CAB USBABMICRO Power supply cord for TY A6 with microUSB output connector Ordering codes GW GSM 02 IQRF GSM gateway Requested option...

Page 13: ...erein are property of their respective owners Legal All information contained in this publication is intended through suggestion only and may be superseded by updates without prior notice No represent...

Reviews: