NOTE: It is recommended that each screw and the material it is being
installed into be able to bear a minimum of 50 pounds (22 kilograms)
of pull force.
4.
Pass the power & data cables through the back box, then install the power/
data back box on the mounting surface.
9. Terminating Power and Data Cabling
Inside the Back Box
Power and data cabling must be routed to the right side (wall-side) of the back
box. Cut all cables with sufficient slack to reach the connector terminals in the
back box but not long enough to be pinched or obstruct the arm installation.
Camera-Side Terminations
Wall-Side Terminations
- RJ-45
- Punch Down Terminal
Screw Terminal
- Direct Power -
12-24VDC or 24VAC
- Trigger In
- Relay Out
1. CONNECTING POWER:
The IQeye Sentinel can be power via Ethernet using an IEEE 802.3af power
source, or powered directly.
-
Powered via PoE:
Input from conforming IEEE 802.3af Power-Over-
Ethernet (PoE) power injector or switch.
-
Powered Directly:
Input voltage is 12-24VDC or 24VAC. IQeye Sentinel
camera/housing modules include built-in bridge rectifier circuitry, so
power wiring polarity can be installed with the + or - on either terminal
without risk of damaging the camera or affecting performance.
Figure 5
7