background image

G C X   S e r i e s

High-Performance Air Cleaning System

User’s Manual

Swiss Made

Summary of Contents for GCX series

Page 1: ...G C X S e r i e s High Performance Air Cleaning System User s Manual Swiss Made...

Page 2: ...and similar appliances Only use this appliance for its intended purpose of air cleaning in non industrial environments Do not use this appliance in areas with very high concentrations of dusts or powd...

Page 3: ...eek Timer 14 4 4 5 Timer ON OFF Fan Speed Selection Menu 14 4 4 6 Timer Information in the Control Panel 15 4 4 7 Time Day Setting 16 4 4 8 Filter Life Reset 16 4 4 9 Changing Airflow Units 17 4 4 10...

Page 4: ...able to reverse the conversion of oxygen O2 into carbon dioxide CO2 caused by breathing and combustion processes 3 Ensure the IQAir system can clean enough air to cope with your room size The actual...

Page 5: ...rtificate of Performance Referral Program I certify that the above information is correct Referrer s Signature The IQAir Referral Program Shell no Serial no Last name First name Company name Phone Add...

Page 6: ...surface such as a wall or a cupboard In general the more centrally the system is positioned the better the performance Position the system close to a power outlet and make sure that the power cord is...

Page 7: ...ffuser is designed for carrying the IQAir system The EvenFlow Diffuser features an omni directional horizontal air outlet Frame 3 to 5 surrounds the 4 gas phase cartridges and filter sleeves to where...

Page 8: ...articulate post filter sleeves hold back abrasion particles from the gas phase filter media 6 Low turbulence low velocity air is returned to the room via the EvenFlow diffuser 3 2 Description of Remov...

Page 9: ...trolling the fan speed and corresponding air delivery rate Checking the remaining filter life of the individual filters Setting the automatic timer Resetting the Filter Life Monitor after replacing a...

Page 10: ...ction in airflow particle filters are clogged or a reduction in filter efficiency gas phase filter is saturated Fan Speed LEDs These LEDs simulate the fan speed through the frequency of their rotation...

Page 11: ...f the IQAir system cfm x 60 air changes per hour ACH air volume of the room cu ft L x W x H Note The air delivery rates of the IQAir system at the various fan speeds settings are listed on the Technic...

Page 12: ...g How the Filter Life Monitor Works The basis for the calculation of the remaining filter life is the already elapsed operation time at the set fan speed This input is compared with an internal memory...

Page 13: ...u key twice 2 Press and hold the Enter key until the cursor starts to flash 3 Press the key once to activate the timer Note If the start and stop time are identical the timer cannot be activated 4 Pre...

Page 14: ...n and exits the enter mode 4 4 4 Day of the Week Timer The Day of the Week Timer allows the deactivation of the Timer ON period on certain days of the week In its default setting the Timer ON period i...

Page 15: ...first line shows the fan speed and the second line shows the airflow The Timer LED is off System on Standby The first line shows the current day and time and the second line shows the next time the sy...

Page 16: ...window press the Enter key Note If the wrong filter has been selected or if you wish to exit the enter mode press the Menu key This leaves the Filter Life unchanged 6 Upon successful reset of the filt...

Page 17: ...e Control Panel 4 4 9 Changing the Airflow Units 1 To reach the air flow units menu from the main display window press the menu key eight times The current airflow unit is displayed 2 You can change t...

Page 18: ...press the OFF key Switching the Timer On and Off If start and stop times have been set in the Daily Timer Menu it is possible to switch the timer on and off with the remote control To switch the timer...

Page 19: ...Control When the battery becomes weak the transmission results will deteriorate and the battery should be replaced The remote control requires one CR2025 battery The battery compartment is located at...

Page 20: ...imply push the locking arms inwards simultaneously until they snap back into the housing IQ Air 20 Chapter 6 Replacing Filters Opening Closing 6 3 1 Troubleshooting when Closing the Housing If the IQA...

Page 21: ...the frame and push them down If known harmful substances are filtered please refer to local regulations or laws for proper filter disposal 6 5 Replacing the Gas Phase Filter Filter 2 and Post Filter...

Page 22: ...ing or after the warranty period please contact your point of purchase or call IQAir Technical Support at 888 560 1020 toll free or email support iqair com To expedite your service request please have...

Page 23: ...fety Screws The only additional tool you need to enable the anti tampering features is a medium size flat head screw driver How to install the power cable fixture 1 Make sure the power cord is unplugg...

Page 24: ...tighten using the supplied tool 7 8 6 9 Plug the red connector of the ribbon cable back into the control panel Ensure that it is pushed in all the way 10 Reinsert the control panel and press it in com...

Page 25: ...side the room OutFlow Complete ducting adapter kit for the creation of negative pressure if placed within the room and positive pressure if placed outside the room PF40 Additional pre filter for areas...

Page 26: ...26 Notes...

Page 27: ...27 Notes...

Page 28: ...090304_IQ_MA_GC_US www iqair com Swiss Made...