6.4 Cooling operation logic
Working status
Working mode
Water in
temperature-T1
For example ,
Tset=28
℃
,
water in
temperature-T1
Heat pump working level
1
Start-up of
heat pump
When you select
the "Smart
working mode "
T1
≦
Tset-1
T1
≦
27
℃
Standby.
2
Tset-1<T1
≦
Tset
27
℃
< T1
≦
28
℃
Silent mode-frequency F2
3
Tset<T1
≦
Tset+1
28< T1
≦
29
℃
frequency
:
F9 -F8-F7,...,- F2
4
T1
≧
Tset+1
T1
≧
29
℃
Powerful mode-F9
5
When you select
the "Silent working
mode".
T1
≦
Tset-1
≦
27
℃
Standby
6
Tset-1<T1
≦
Tset
27
℃
< T1
≦
28
℃
Silent mode - frequency F2/F1
7
T1>Tset
T1>28
℃
Smart mode -frequency F5
8
When you select
the "Powerful
working mode."
T1>Tset-1
T1>27
℃
Powerful mode-frequency
F10/F9
9
T1
≦
Tset-1
T1
≦
27
℃
Standby
10
Re-start to
cool water
in standby
status
Smart
T1
≦
Tset-1
T1
≦
27
℃
Standby
11
Tset
≦
T1 <Tset+1
28
≦
T1 <29
℃
Silent- frequency F2
12
Tset+1
≦
T1 <Tset+2 29
≦
T1 <30
℃
Frequency: F2 -F3-F4,...,- F9
13
T1
≧
Tset+2
T1
≧
30
℃
Powerful mode -frequency F9
14
Silent
Tset<T1
≦
Tset+1
28< T1
≦
29
℃
Silent mode-frequency F2/F1
15
T1
>
Tset+1
T1
>
29
℃
Smart mode-frequency F5
16
Powerful
T1
>
Tset+1
T1
>
29
℃
Powerful mode-frequency
F10/F9
17
T1
≦
Tset-1
T1
≦
27
℃
Standby
Summary of Contents for Theratherm 17iv
Page 1: ...Swimming Pool Heat Pump User and Service Manual ...
Page 2: ......
Page 5: ...3 A Division of 2 Dimension mm Model Theratherm 17iv ...
Page 6: ...4 A Division of Model Theratherm 30iv ...
Page 13: ...11 A Division of Dry contact pump connection ...
Page 14: ...12 A Division of ...
Page 38: ...36 A Division of ...
Page 43: ...41 A Division of 4 4 Parameter Query ...
Page 45: ...43 A Division of ...
Page 47: ......
Page 48: ......
Page 49: ......
Page 50: ...A0141PXV01 ...