19
A Division of:
0: No frequency limit; 1: Coil pipe temperature limit;
2: Overheating or overcooling frequency limit; 4: Drive Current frequency limit;
8: Drive voltage frequency limit; 16:Drive high temperature frequency limit
6.2.7
Parameter setting
Select
and press
to enter, press
and
to choose P0-P18 value and press
to set.
Note: Long press
for 15s to set P12, P13, P14, P15, P17.
6.2.8
Error code
Select
and press
to check the error code. If the HP is normal,
button is invalid. For example,
Code
Name
Scope
Default
Remark
P0
Mandatory defrosting
0-1
0
0: Default normal operation
1: mandatory defrosting.
P3
Water pump
0-1
0
1:Always running;
0:Depends on the running of compressor
P7
Water temp. calibration
-9
~
9
0
Default setting: 0
P12
MOBUS COM
0 - 5
0
Modbus Only
(
default value after reset
)
P13
MODBUS ID Address
1 - 88
9
Modbus Only
(
default value after reset
)
P14
Restore to factory settings
0-1
0
1-Restore to factory settings
,
0- default
(
restore
P0
、
P3
、
P7
、
P8
、
P9
、
P10
、
P11 to factory setting)
P15
P value
/
/
Depend on the machine
P16
Start code
/
/
Depend on the machine
P17
WiFi/MODBUS
0-1
0
1
—
WiFi
,
0
—
MODBUS
Summary of Contents for Theratherm 17iv
Page 1: ...Swimming Pool Heat Pump User and Service Manual ...
Page 2: ......
Page 5: ...3 A Division of 2 Dimension mm Model Theratherm 17iv ...
Page 6: ...4 A Division of Model Theratherm 30iv ...
Page 13: ...11 A Division of Dry contact pump connection ...
Page 14: ...12 A Division of ...
Page 38: ...36 A Division of ...
Page 43: ...41 A Division of 4 4 Parameter Query ...
Page 45: ...43 A Division of ...
Page 47: ......
Page 48: ......
Page 49: ......
Page 50: ...A0141PXV01 ...