background image

MANUFACTURER'S EXTENDED WARRANTY

In addition to your statutory rights relating to this product it is also guaranteed by IQ (Europe)
Limited ("IQ") for 12 months from the date of purchase against faulty materials or workmanship
which affect its designed ability to detect or switch.  During this period if the product has a defect
of this nature it will be repaired or replaced free of charge by IQ with the same item, or a similar
one of higher specification, ON CONDITION THAT:-

The buyer takes advantage of any 'return to store' scheme operated by the seller from whom it is
bought.

If the product has a defect outside the period of any seller's 'return to store' scheme it should be
returned to IQ (Europe) Limited at Sandbeck Lane, Wetherby, W. Yorks LS22 7TW, England at
the expense of the buyer together with evidence of the date of purchase (it is the responsibility of
the buyer to prove delivery to IQ).

The product has been bought by the user.

The product has not been misused or handled carelessly, installed incorrectly, or used on a 
voltage supply other than that shown on it.

Repairs have not been attempted by anyone other than IQ's staff.

The product has been used for domestic purposes only.

The product has not been installed in any unusually exposed or harsh environmental conditions.

If the buyer is resident in the EU the product or its replacement will be returned to the buyer at
the expense of IQ. 

This guarantee excludes liability for discolouration of paint or plastic, or any user replaceable
parts and in particular lamps, glass panels, or globes/lanterns. It does not confer any rights other
than those expressly set out above and does not cover any claims for consequential loss or 
damage. 
This guarantee is offered as an additional benefit and does not affect your statutory rights as a 
consumer.

This contract is subject to the laws of England and Wales.

*** IMPORTANT ***

As of 1 January 2005, changes to the Building Regulations affect domestic electrical installations in

England and Wales. You don't need to be a qualified electrician to make changes to your home's electrical

system, but the work must be done in accordance with the Regulations. 

Where you employ an electrician who is a member of a competent person self-certification scheme, they

will be able to certify the work complies with the Regulations.

If you decide to carry out the work yourself we recommend that you make yourself aware of the

Regulations before you begin and if you require any clarification you should contact your Local Authority

Building Control Department.

Details of the Building Regulations can be obtained on the internet via the government website

www.odpm.gov.uk/explanatory-booklet 

SF-PTV180-500-T.qxd  13/04/2005  13:51  Page 2

Summary of Contents for E-994

Page 1: ...r IQ Europe Limited Sandbeck Lane Wetherby LS22 7TW Visit us at www iq europe co uk Installation helpline 0871 717 1100 E 994 V1 0 04 05 I N S T A L L E R G U I D E IQ PTV180 500 TX T SF PTV180 500 T qxd 13 04 2005 13 51 Page 1 ...

Page 2: ...nvironmental conditions If the buyer is resident in the EU the product or its replacement will be returned to the buyer at the expense of IQ This guarantee excludes liability for discolouration of paint or plastic or any user replaceable parts and in particular lamps glass panels or globes lanterns It does not confer any rights other than those expressly set out above and does not cover any claims...

Page 3: ...GHT TRANSMITTER SELECTING THE LOCATION For optimum performance mount at 2 5m 8ft high The sensor can be pointed in any direction as long as it is within 100m of the receivers it is to be used with The sensor can detect motion up to 12m within a 180 degree radius Avoid areas where pets or traffic may trigger the sensor Avoid mounting where the Sensor aims at objects that change temperature rapidly ...

Page 4: ... the wall plate See diagram F Mark the position of the fixing holes Ensure wall plate is correctly positioned diagram G Note TOP engraving on inside of wall plate Drill the holes Insert wallplugs into the holes PIERCE PASS THE CABLE THROUGH THE GROMMET BEFORE SECURING WALL PLATE TO WALL It is recommended that the grommet is pierced with a screwdriver to ensure a better seal Fix the wall plate to t...

Page 5: ... lamp will illuminate for approximately 30 seconds This indicates the unit is wired correctly After approximately 30 seconds the light will turn off Slide the TIME on switch to point to TEST setting The light will now illuminate for approx 5 seconds after each detection to allow you to determine the detection pattern The LEDs will scroll from left to right and on detection the LEDs will turn off T...

Page 6: ... to right indicating that the unit is in Automatic Mode and on detection of movement the LEDs will turn OFF and turn the Halogen lamp ON to indicate a signal has been sent to the receiver MASKING THE SENSOR LENS To restrict the sensor coverage preventing detection in unwanted areas mask the sensor lens using the masking tape provided in the accessory pack see diagram D For your information the top...

Page 7: ...S detection Restrict long detection Restrict short detection Lens Mask Less sensitive More sensitive TOP VIEW 180º SIDE VIEW 12m 2 5m A C B D Photocell Sensitivity TIME TEST 1 5 12min MIN MAX SF PTV180 500 T qxd 13 04 2005 13 51 Page 7 ...

Page 8: ...E H G 1 F 2 UP SF PTV180 500 T qxd 13 04 2005 13 51 Page 8 ...

Page 9: ...a soft cloth Do not touch the bulb with your bare hand as it will shorten the life of the bulb 1 Switch off the floodlight Do not touch the Floodlight while it is in use or still hot Allow it to cool about 5 minutes before touching it 2 Replacement bulb type is 240V mains halogen 500W or 300W R7S cap floodlight bulb 3 Isolate the mains supply and then unscrew cover screw on the top of the unit 4 O...

Page 10: ...eriod should never exceed 1 minutes Occasionally winds may activate the sensor Sometimes passages between buildings etc can cause a wind tunnel effect Ensure the unit is not positioned so as to allow detection of cars people using public thoroughfares adjacent to your property Check that the power is switched ON at the circuit breaker internal wall switch Turn OFF the power to the unit and check t...

Page 11: ... up to 40 in running costs whilst also conserving precious nat ural resources LIGHT POLLUTION CONSIDERATE LIGHTING Please be aware of the annoyance over lighting an area can cause to your immediate neighbours Light pollution caused by incorrectly installing a unit or over lighting an area can be limited by carefully considering the location and position of your unit before installation The light s...